DOCOL 00645106 Manual - Page 10
Browse online or download pdf Manual for Plumbing Product DOCOL 00645106. DOCOL 00645106 13 pages.
Maintenance 00621306 / 00662306
SYMPTOMS
Water does not flow:
Solenoid valve produces an audible "click", Led
lights up the escutcheon
Water does not flow:
Solenoid valve does not produces audible "click",
the LED does not light up the escutcheon
Exit water: Led escutcheon of lights or no lights
partially
Water flows intermittently
Low flow
Non-aerated water jet
Maintenance 00621306 / 00662306
SYMPTÔMES
L'eau ne fait pas:
Electrovanne produit "click" audible, la LED
s'allume la rosace
L'eau ne fait pas:
Électrovanne ne produit pas de
"click"
pas de lumière Led de la rosace
Sortez de l'eau : Rosace Led ne pas clair
jusqu'à ou partiellement
Sortez de l'eau coule par intermittence
Faible débit
Jet d'eau non aérée
POSSIBLE REASONS
Water supply failure
Inlet flow control
Unavailability of electricity to the sensor
Power cord is not connected in the electrical outlet
Bad connection between sensor and power supply
Sensor not connected to the solenoid valve
Sensor boot faiture
Faulty sensor cable
Faulty sensor
Sensor not connected to escutcheon
Led light escutcheon damaged
Sensor damaged
Sensor cable / broken escutcheon
Infiltration of water between escutcheon and bench
Sensor boot faiture
Sensor damaged
Inlet flow control not enough open
Air inside pipe system
Dirt in the pipe
Water supply stop is partially closed
Water supply stop is partially closed
Product installed in a pressure below
1,0 kgf/cm² / 1,0 bar / 10 m.c.a
CAUSES PROBABLES
Indisponibilité de l'eau au point
Saleté dans le tuyau
Indisponibilité de l'électricité à la sonde
Source de tension non connecté au réseau électrique
Source de tension n'est pas reliée au capteur
Capteur n'est pas connecté à clapets
sonore,
Échoué de l'initialisation de capteur
Câble de la sonde cassée
Capteur endommagé
Capteur non raccordé à la rosace
Conduit la rosace brûlé
Capteur endommagé
Câble du capteur / rosace cassé
infiltration d'eau entre la rosace et banc
Échoué de l'initialisation de capteur
Capteur endommagé
Réglage de la RRD (Régulateur de débit d'inscription)
Air dans le tuyau
Dirt dans le pipeline
Aérateur obstrué
Bilan global est partiellement fermé
Installation en une pression ci-dessous
1,0 kgf/cm² / 1,0 bar / 10 m.c.a
SOLUTIONS
Open water supply stop valve
Open the Inlet flow control
Disassemble and clean the core of Inlet Flow control filter.
Verify overload protect
Connect power cord to power inlet
Connect the cableas again
Reconnect the sensor cable to the valve
Disconnect and reconnect power cable
Available at Docol Authorized Distributor in your country
Available at Docol Authorized Distributor in your country
Connect the sensor cable to the cable escutcheon
Available at Docol Authorized Distributor in your country
Available at Docol Authorized Distributor in your country
Available at Docol Authorized Distributor in your country
Checking the sealing of the escutcheon
Disconnect and reconnect power cable
Available at Docol Authorized Distributor in your country
Rotate the cartridge clockwise RRC
Open the network elsewhere in the network and bleed (let out until water stops
coming out with air and water)
Disassemble and clean the core of Inlet flow control filter
Remove, clean and reinstall the aerator
Fully open the general log
Remove the flow restrictor ( See page 7)
SOLUTIONS
Ouvrir le journal général
Ouvrez RRD (Régulateur de débit d'inscription)
Retirer la crépine et nettoyez le RRD
Vérifiez le disjoncteur et réinitialiser
Branchez le cordon d'alimentation au point de l'électricité
Connecter le câble à partir de la source vers le câble du capteur
Reconnectez la valve de câble de capteur
Débranchez et rebranchez le câble d'alimentation
Contacter un revendeur agréé Docol dans votre pays.
Contacter un revendeur agréé Docol dans votre pays.
Branchez le câble du capteur à la rosace câble
Contacter un revendeur agréé Docol dans votre pays.
Contacter un revendeur agréé Docol dans votre pays.
Contacter un revendeur agréé Docol dans votre pays.
Vérifier l'étanchéité de la rosace
Débranchez et rebranchez le câble d'alimentation
Contacter un revendeur agréé Docol dans votre pays
Tournez la cartouche dans le sens horaire RRD
Ouvrir le réseau ailleurs dans le réseau et de purge (laisser sortir l'eau jusqu'à
ce que l'air cesse de sortir avec de l'eau)
Retirez l'objet
Retirez, nettoyez et réinstallez l'aérateur
Entièrement ouvrir le journal général
Retirer le limiteur de débit ( Voir la page 7)
13