Replacement Parts
Part No.
Description
529-05-22
Carbon monoxide sensor
523-01-29
Replacement filter kit
Accessories
Part No.
Description
529-05-16
Span Gas Cylinder, 3.6 cubic feet of gas
(replacement Span gas for large kit. 529-04-48)
529-05-17
Zero Gas Cylinder, 3.6 cubic feet of gas
(replacement Zero gas for large kit, 529-04-48)
529-05-18
Zero Gas Cylinder, 0.6 cubic feet of gas
(replacement Zero gas for small kit, 529-04-49)
529-05-19
Span Gas Cylinder, 0.6 cubic feet of gas
(replacement Span gas for small kit, 529-05-49)
529-05-20
Remote Alarm Audible, 119 dBA
529-05-21
Remote Alarm, Strobe Light, 150,000 CP (requires 529-04-50)
529-05-23
Y-Plug Adapter
529-04-48
Calibration Kit, Large
529-04-49
Calibration Kit, Small
529-04-50
Adapter, 110-120 Volt
Set Up Procedures
The 3M filter and regulator panel, when used in accordance with the following instructions, will
remove or reduce selected contaminants from compressed air lines. (Fig. 4)
The 3M™ Portable Compressed Air Filter and Regulator Panel 256-02-01, with CO monitor
should not be used when the air entering the filter is oxygen deficient. These units will not
increase the oxygen content of oxygen deficient air. Use with oxygen deficient air may result
in sickness or death.
The 3M filter and regulator panel can be wall mounted right in the case. Simply drill holes in the
back of case to allow for installation of screws or bolts. Use washers on the screws or bolts to
prevent the screws from pulling out from the unit.
The user's supply line to the inlet of the 3M filter and regulator panel should be a minimum of
3/4" I.D. The air supply entering the filter and regulator panel should meet the following criteria
to insure maximum efficiency of the filter system:
– Temperature range should be 35-150°F (2-65°C)
– Large amounts of aerosols of oil, water, and other liquids should be removed prior to
entering the filter and regulator panel (greater than 50 ppm - oil and water aerosols plus solids).
Conditioning equipment may be necessary prior to the filter and regulator panel to control the air
temperature and bulk liquid removal.