3M 6000 User Instructions - Page 11

Browse online or download pdf User Instructions for Respiratory Product 3M 6000. 3M 6000 15 pages. Half facepiece respirator
Also for 3M 6000: User Manual (4 pages), User Instructions (16 pages), Technical Data Sheet (5 pages), Instruction Sheet (2 pages), Instruction Sheet (8 pages), User Instructions (2 pages)

3M 6000 User Instructions
3. Disinfect facepiece by soaking in a solution of quaternary ammonia disinfectant or sodium hypochloride (1oz. [30ML] household bleach in 2
gallons [7.5L] of water), or other disinfectant.
4. Rinse in fresh, warm water and air dry in non-contaminated atmosphere.
5. Respirator components must be inspected prior to each use. A respirator with any damaged or deteriorated components should be repaired or
discarded.
6. The cleaned respirator should be stored away from contaminated areas when not in use.

REPLACEMENT PART INSTRUCTIONS

3M™ Facepiece Assemblies for 6700/6800/6900
The facepiece consists of the head harness assembly, nose cup assembly, center adapter assembly, lens assembly, faceseal (small, medium or large),
and frame assembly (top, bottom, nuts and screws).
To disassemble lens assembly from faceseal, remove the two Phillips screws from top frame. Then, pull the frame top and frame bottom away from
the faceseal. The frame top, frame bottom, faceseal and the lens assembly have vertical line markings that indicate their positions relative to one
another. Make certain these markings are aligned for reassembly.
3M™ Center Adapter Assembly 6864 Replacement
The center adapter assembly consists of center adapter base, cover, exhalation valve, and adapter gasket. It is secured to the center port of the lens
with a bayonet style twist lock connection, which compresses the sealing gasket.
To remove the center adapter from the facepiece:
1. Remove nose cup assembly by pulling away from center adapter inside facepiece (Fig. 15).
2. Grasp center adapter at cover and twist counter-clockwise 1/4 turn to disengage bayonet from facepiece lens.
3. Withdraw center adapter from lens center port.
To install the center adapter into the facepiece:
1. Align tabs on center adapter base with notches in center port of facepiece lens.
2. Slide adapter into lens port (Fig. 16).
3. Grasp center adapter at cover and twist clockwise 1/4 turn to stop. Be certain center adapter gasket is properly in place and sealed, and that the
adapter assembly is fully engaged.
4. Replace nose cup assembly.
Converting from the Standard Center Adapter 6864 to the DIN Port Adapter 6884
Any 3M™ Full Facepiece 6000 Series can be converted to the desired center adapter assembly by following the instructions in 3M™ Center Adapter
Assembly Replacement and installing the Bayonet Caps 6880 with Inhalation Port Gaskets 6895 or the Full Face Plug 7800 with Breathing Tube
Gasket 6876 as appropriate.
Fig. 15
6800_w6864.eps
8/16/04 K&K
Fig. 16
6898 w/6864asmbl
4/12/04 K&K
11
(English)