4.0.0 Operators Parameters:
4.0.0
4.0.1
Soft Strt.
4.1.0
4.1.1
Strt Del.
4.1.2
TR-stp
4.1.3
Wiper
4.1.4
INTERL
SPEEDS: rpm (spm, stitches per minute)
Soft start after End of Cycle
Range: 150 to 1000
Steps:
10
Default:
700
TIMERS
ms (milliseconds)
Start Delay
The delay from presser foot down to start.
If the foot is already down, this time will not affect.
Range:
30 to 2500
Steps:
10
Default:
60
Trim
Clinton trim system: Stop time
If this time is zero (0), the machine will not stop
Chain stitch: Trim-on time
Range:
0 to 2500
Steps:
10
Default:
80
Wiper Time
Range:
10 to 2500 (large timer for pneumatic wiper)
Steps:
10
Default:
80
Interlock time The time a new start is suppressed after trim
Range:
10 to 300
Steps:
10
Default:
30