Dodge Quantis MSM Instruction Manual - Page 6

Browse online or download pdf Instruction Manual for Industrial Equipment Dodge Quantis MSM. Dodge Quantis MSM 16 pages.

Dodge Quantis MSM Instruction Manual
These mounting arrangements are for all output configurations and output shaft types.
IMPORTANT: When ordering, please specify mounting position for correct oil quantity. In cases of mounting position other than
shown here with regard to the oil quantity, please reference the Incline Mounting page in the Quantis Engineering Catalog, and contact
Application Engineering.
NOTE: The oil volumes shown are approximate values and cannot be used to correctly set the reducer oil level. ALWAYS fill
the reducer to the correct oil level plug and recheck in 1 week.
Unit Size
Reduction Stage
2
38
3
2
48
3
2
58
3
2
68
3
2
88
3
2
108
3
2
128
3
2
148
3
2
168
3
Unit
Reduction
Input
Size
Stage
Reducer
Pints
4
0.8
68
5
1.3
4
1.5
88
5
3.2
4
1.5
108
5
3.2
4
3.1
128
5
3.2
4
3.1
148
5
3.2
4
3.1
168
5
5.3
NOTES:
All MSM 38 units are sealed for life and furnished with only one plug for filling and draining.
4 and 5 stage reduction reducer consists of two reducers assembled to each other, the Input Reducer and the Primary Reducer. The reducers are
sealed from each other and require different oil levels per the chart.
* Hole location on opposite side of reducer.
Motorized Shaft Mount (MSM) Reducers and Integral Gearmotors
A3
Pints
1.7
1.7
3.0
3.2
4.6
4.8
5.9
6.1
14.2
13.7
18.8
19.2
30.0
31.5
46.1
46.1
67.8
69.1
A3
Input
Primary
Reducer
Reducer
Liters
Pints
0.4
6.6
0.6
6.6
0.7
13.6
1.5
13.6
0.7
18.7
1.5
18.7
1.5
31.0
1.5
31.0
1.5
46.9
1.5
46.9
1.5
68.5
2.5
68.5
Liters
Oil Level
0.8
0.8
1.4
*
1.5
2.2
2.3
*
2.8
2.9
6.7
6.5
8.9
9.1
14.2
14.9
21.8
22.3
32.1
32.7
* *
Primary
Reducer
* *
Liters
3.1
3.1
6.4
6.4
8.8
8.8
14.7
14.7
22.2
22.2
32.4
32.4
6
A3 – Horizontal – Ceiling Mount
Ventilation
A A
A A
Oil Drain
Sensor
MN1617