Technical Data

Power supply
rated voltage
AC
current input
current input (at switching moment)
rated voltage
DC
current input
current input (at switching moment)
Control input
control voltage
control current
DC
control pulse duration
push-button bounce time
Relay output
1 signal relay (DFA blocked)
voltage
AC/
DC
rated current
Terminals
type
terminal cross-section
tightening torque
Housing
type
dimensions
material
Other data
operating temperature*
humidity
type of protection
installation regulations
Article numbers / accessories
remote actuator DFA 2-2
power supply unit RK 24
* Mind the maximum permissible temperature of the mounted RCCB.
18
minimum
21,6 V
AC
55 mA
21,6 V
DC
24 mA
21,6 V
DC
60 ms
screw terminal with strain-relief clamp
0,4 mm Ø
distribution board housing in accordance with DIN 43880 for
mounting on DIN rail in accordance with DIN EN 60715
72 x 85 x 58 (W x H x D in mm) / 4 module widths
polyamide (PA)
- 25 °C
max. 85 % (exposure to dew not permissible)
DIN EN 50557, DIN EN 55014-1
typical
24,0 V
AC
60 mA
24,0 V
DC
27 mA
24,0 V
DC
1 mA
IP 20
09 100 113
09 980 654
maximum
30 V
AC
65 mA
600 mA
26,4 V
DC
30 mA
500 mA
26,4 V
DC
10 ms
24 V
1.000 mA
2,5 mm²
0,6 Nm