Cyfral CC-4000 Operating, Installation And Programming Manual - Page 4
Browse online or download pdf Operating, Installation And Programming Manual for Control Unit Cyfral CC-4000. Cyfral CC-4000 8 pages. Control electronic

Subscribers' entry codes. There are four different four-digit codes assigned to each physical address of uniphone
1-255. When using the codes from the producer code table, it should be taken into account that the codes refer to
physical addresses and not to subscriber's numbers. Nonetheless, if the table of subscribers is set in a 1:1 ratio,
then the physical address corresponds to the subscriber number.
Proximity keys for subscribers, eight keys per one property
Non-recorded keys in the amount of 1024 pcs
In addition, there is a factory table of opening codes in the memory which can be restored at any time. (It cannot be
deleted by the installer/user).
The CC-4000 electronics is powered by 12-13.8V and 40mA DC. It should be assumed that the power supply
should have a current efficiency of 2.5A. The SLAVE panel is powered from its terminals.
3.
I
NSTALLATION METHODS
I
NTEGRATED ELECTRONICS
devices. It is mounted on four plastic pins. To ease installation of a flush-mounted box, the electronics board can be
removed from the pins.
E
LECTRONICS RAISED
4.
C
ONNECTING
The power supply is connected to a double threaded connection marked with terminals +12V and GND. The
power supply cables should ensure the lowest possible voltage drop. Approx. 1 mm
meters of the power supply cable should be assumed. Single UTP cables are not suitable for this, because their
cross-section is 0.2mm
Correct connection of the power supply is indicated by a LED. If supply voltage falls below 10V, the LED will go off.
When below 8V, the control panel will be reset.
The power supply system is protected against reverse polarity and overvoltage.
Most switched-mode DC power supplies are commercially available with output voltage regulation. If it is possible,
it is recommended to adjust this voltage to 13V. This will allow to compensate for any voltage drops in the supply
cables.
Uniphone and video line is a quadruple threaded connection marked as LINE. Cables for L + and L- uniphones
should be connected with one pair of cables, as well as
The resistance of wires in the uniphone line should not exceed 300 Ohm between the farthest devices and the
CC-4000 board. Otherwise, it may be difficult to establish a connection.
in the PC-4000 panel housing. This method allows you to minimize connections between
outside the panel. Installed in a surface-mounted plastic housing.
A
2 which will ensure correct operation at a distance of up to four meters.
VH
and
VL
video cables.
~4~
A
2 of cross-section for every 20