Cyndar Electronic Technology HL-1612 Product Manual - Page 14
Browse online or download pdf Product Manual for Measuring Instruments Cyndar Electronic Technology HL-1612. Cyndar Electronic Technology HL-1612 14 pages. Safety edge sensor
Safety characteristics
PL Performance Level L
Category Category
SIL CL
PFH d [1 / h]
7.Safety contact precautions
1)
Storage and use environment requirements Do not save or use this product in a long-term direct sunlight
environment.
Do not save and use it outside of the ambient temperature-35 ℃ to + 80 ℃.
Do not save and use it outside of air pressure 86 " 106KPa.
Do not preserve and use them in the environment containing strong corrosive or combustible gases;
2) Installation precautions
Do not lift or move the safety contact by pulling the cable.
Use a special bracket to install a safety touch edge.
Do not fold or punch on the edge of the safety contact.
Do not install the safety edge on the surface raised area, but on a flat, smooth surface.
3)Use precautions
Be sure to use the safety contacts in this marking voltage range or with the safety relays matched in this
description.
Do not apply a load for long times, or it may cause damage to the safety touch edge.
Do not dip safety edges in water or for frequent splashing.
Please strictly follow the chemical resistance of the product.
EN ISO 13849-1:2015
EN ISO 13849-1:2015
EN 62061:2005 + A2:2015
EN 62061:2005 + A2:2015
PLe
Cat.4
SIL CL 3
2.10E-09
14