PS-55, PS-55C, PS-110
Power Supply Operational Manual
Front View of PS-55C
The PS-55 C is a smaller lighter power supply enclosed in a plastic case.
It has a lower output which is why it can only be used properly with
the smaller lighter torque drivers.
Front View of PS-55 and PS-110
The ON / OFF switch will illuminate when the switch is turned to the ON position. The HIGH/
LOW switch will change the DC output voltage from 30 VDC to 20VDC. The PS-110 can
power 2 drivers at the same time. NOTE: while the PS-110 unit can power two screwdrivers
simultaneously both drivers will operate at the same speed setting as determined by the
position of the HIGH/LOW switch.
CE Approval
The PS-55 and PS-110 carry the CE approval. The PS-55C does not, but is double insulated for
electrical safety and uses the same PC board assembly as the PS-55. The PS-55C does provide a
ground path through the 3rd pin on the plug.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
888) 486-6163
216) 481-4519
Rear View of PS-55 and PS-110
•
The PS-55 can operate either on 110-115 VAC or
220-230 VAC by selecting the desired voltage on
the slide switch located on the back of the units.
NOTE: 220 VAC option not available on PS-110.
•
Only the PS-55 is designed to connect to the STC-02
Screw Counter, ASG # 65646.
•
Optional cable, #65705 is available to connect the
PS-55 to a PLC or other equipment to provide a
momentary dry contact / relay closure signal when
the clutch shuts off.
Cord, Fuse, Circuit Breaker
•
The PS-55 and PS-110 all have a detachable IEC style
AC cord. The AC cord supplied with the units have the
correct style plug for operating in the US. If you are
using the unit on 220-230 VAC, or outside the US where
a different style connector is needed, these can be
acquired locally.
•
All units have an internal circuit breaker protecting the
DC output. If the breaker opens, turn the power off and
wait a few minutes to allow the circuit breaker to reset.
If the breaker is continually opening it could mean
you have a problem with the tool or the tool power
cord, the power supply or have selected the wrong
screwdriver or power supply for the application. Contact ASG.
•
The AC FUSE on the PS-55 and PS-110 is located in the IEC connector on the back of the
units along with a spare fuse. The spare fuse is located in the rear "pocket" of the fuse
holder. The part # for the replacement fuse is # 720318, or use a GMA-2R Bussman 2
Amp fuse or equivalent. NOTE: The PS-55C has a hard wired cord and can be operated on
110-115 VAC ONLY. The PS-55C AC FUSE is inside the case and is not recommended to be
replaced by the user.