(7). RS-232 Control of the CSC-210 Video Scaler
The Video Input selection and signal parameter setting for the CSC-210 can
also be controlled via an external control system by using the RS-232 port on the
unit. If information for this control method is required,beyond the scope of the
instructions provided in this section, please contact Cypress Technology Support,
A disk is provided with the CSC-210 containing a sample Windows Control Panel
that permits remote control of the unit from a PC via RS-232.
* The Connection between video scaler and remote controller with RS-232
modem cable.
Video Scaler
PIN
1
2
3
4
5
6
7
8
9
* RS-232 transmission format:
Baud Rate : 9600 bps
Data Bit : 8 Bits
Parity: None
Stop Bit: 1 bit
Flow control:None
Definition