The DeckMaster comes fitted with a harness and connector ready for direct plug-in to the Universal II controller. While
this is configured for "plug and play" installation, removal of the connector to run through a bulkhead may be necessary
from time to time. In that event, or in the event of troubleshooting, the following table is provided for reference.
Deutsch Plug for J2 Connector on Controller (Part No. HDP26-18-14SN-L017)
Contact Position
Wire Color
A
B
C
(Sealing Plug)
D
E
Green
F
(Sealing Plug)
G
Orange
H
J
White/Black
K
Red/Black
L
Green/Black
M
Orange/Black
N
Blue/Black
P
Black/White
Table 2 – Monitor Harness Connections
FIGURE: 5
P
N
E
D
A
C
F
B
G
H
J
FRONT VIEW
3440 DeckMaster with UII control Initial setup
The following functions can be configured in the setup mode:
• Monitor Orientation (sideways or inverted mounting)
• Restore Factory Defaults
• Obstacle Avoidance
• Electric Riser Disable/Enable
• Stow and Deploy Positions
To enter the setup mode, follow these steps:
1. Turn power off to the Universal II Controller.
2. Press and HOLD the Stream switch (can be done on the Joystick or the Toggle Switch Box).
3. Turn power on to the Universal II Controller while continuing to hold the Stream switch.
4. Wait 3-4 seconds and release the Stream switch.
The Universal II Controller should now be in setup mode. When in setup mode, the LED on the operator station will
be slowly blinking (a short blink followed by a long pause). If it is not slowly blinking, repeat steps 1-4 above.
Black
Power Out – Switch and Position Sensor (−)
White
Input – Rotation Switch (Voltage)
Input – Multifunction #2 (Unused)
Red
Input – Swing Arm Position Sensor (Voltage)
Power Out – Position Sensor (+5 VDC)
Data – Lin Bus (Unused)
Output – Rotation Motor (Right)
Blue
Output – Rotation Motor (Left)
Output – Elevation Motor (Up)
Output – Elevation Motor (Down)
Output – Pattern Motor (Stream)
Output – Pattern Motor (Fog)
Output – Swing Arm Motor (Deploy)
Output – Swing Arm Motor (Stow)
DEUTSCH
HDP 26-18-14SN-L017
M
L
K
SIDE VIEW
Function
P
N
C
M
B
L
K
REAR VIEW
Page 9
DEUTSCH
0411 -310-1605
E
D
F
A
DEUTSCH
0462 -201-16141
G
H
J
SOCKET
CONTACT
CONTACT
REMOVAL TOOL