EN – TECHNICAL USER GUIDE
INTRODUCTION
This manual covers the installation; mounting, electrical installation and setup of the iDOL 63 Cloud Gateway. The manual provides the user,
installer and electrician with the basic knowledge on how to mount and connect the iDOL 63 to the Omni cloud.
The electrical installation section is intended primarily for electricians commissioning and servicing the system.
Please be aware that the iDOL 63 may not be opened without first removing the supply voltage, and
that service and troubleshooting may only be done by qualified personnel.

PRODUCT DESCRIPTION

The iDOL 63 Cloud Gateway collects data from the attached DOL sensors and sends these data to the DOL Omni Cloud.
SETUP
The full process for unboxing the iDOL 63 to fully operational is for short described by the following steps:
Unbox and install the iDOL 63 as described in this manual. This includes mounting and electrical installation
Install local network in the stable and connect into the Internet/WAN
Use POE via the internet cable
Make sure to read the full guide before you start mounting the iDOL 63.
MOUNTING
The iDOL 63 must be mounted in the walking area or control room, not directly inside the stable area together with the animals.
Mount the sensors inside the stable area according to the installation instructions found in the sensor documentation.
iDOL 63 is delivered with a mounting bracket.
Figure 1: Mounting bracket
dol-sensors a/s
Mount the bracket onto the back of the
box with the two 4x10 TX20 screws
provided. Note that the bracket should
be mounted furthest away from the
cable inlet holes in the bottom.
Agro Food Park 15 - 8200 Aarhus N - T: +45 7217 5888 - F: +45 7217 5959
Mount iDOL 63 to the wall using suitable
fasteners for the wall material.
www.dol-sensors.com