Ashcroft F5509 Installation And Maintenance Instructions Manual - Page 2
Browse online or download pdf Installation And Maintenance Instructions Manual for Measuring Instruments Ashcroft F5509. Ashcroft F5509 8 pages. Differential pressure gauges
Installation and Maintenance Instructions for
F5509/F6509 Differential Pressure Gauges
1.3 Limits of liability
Refer to Ashcroft standard terms of sale for limits of
liability.
1.4 Copyright
This Operating Manual may only be copied and passed on as
a complete document without the special permission of the
publisher.
1.5 Warranty For the product described here, we offer a
warranty pursuant to our General Terms and Conditions on
Delivery and Payment, Section 6: Liability for Defects.
1.6 Manufacturer's addresss, customer service
Ashcroft, Inc.
250 East Main Street
Stratford, CT 06614-5145, U.S.A
Tel: (203) 378 8281
Fax: (203) 385 0408
2 SAFETY
2.1 General sources of hazards
Pressure gauges are pressurized parts where failure can result
in hazardous situations. The selection of pressure gauge should
be made in accordance with the rules set out in EN
2.2 Use in accordance with intended purpose
The devices are only to be used for the intended purpose as
described by the manufacturer. The devices are used for direct
display of differential pressure.
The integrated switching elements are magnetic spring
contacts or inductive proximity switches with a groove design,
supplied by isolating switch amplifiers. If the set limit values are
exceeded, the output circuits are opened or closed.
For each use scenario, the corresponding set-up regulations
must be respected. The use in explosion risk areas is not
permitted.
2.3 Operator's responsibility
Safety instructions for proper operation of the device must be
respected. They are to be provided by the operator for use by
the respective personnel for installation, servicing, inspection
and operation. Risks from electrical energy and from the
released energy of the medium, from escaping media and from
improper connection of the device must be eliminated. The
details for this are to be found in the corresponding applicable
set of regulations, such as DIN EN, UVV (accident prevention
regulations) and in sector-specific instances of use (DVWG,
Ex-. GL, etc.) the VDE guidelines and the regulations supplied
by local utilities companies. The device must be taken out of
service and secured against inadvertently being restarted, if
the presumption is that risk-free operation is no longer possible
(see Chapter 10: Faults). Altering the gauge by the customer is
not permitted. This also applies to installation of spare parts.
Possible conversions or alterations may only be carried out
by the manufacturer. The operational safety of the device is
only guaranteed when it is used for its intended purpose. The
specification of the device must be adapted to the medium
used in the plant. The limit values indicated in the technical
data must not be exceeded. The safety information detailed in
© Ashcroft Inc. 2018, 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0357, www.ashcroft.com
All sales subject to standard terms and conditions of sale. F5509_gauge_im1.0, Rev. A, 08/18
this Operating Manual, existing national regulations for accident
prevention, and the operator's internal regulations regarding
working, operations and safety must be respected. The
operator is responsible for all specified servicing, inspection
and installation works being carried out by authorized and
qualified specialists.
2.4 Installation recommendations
The gauge may only be installed and started up by specialist
staff who are familiar with installation, start-up and operation of
the product. Specialist staff are people who are able to assess
the work assigned to them on the basis of their specialist
training, their knowledge and experience and their knowledge
of the relevant standards, and can identify possible risks.
2.5 Signs/Safety markings
The pressure gauge and its surrounding packaging carry
markings. These markings show the article number,
measurement range, maximum static pressure, maximum
overload and manufacturer. The pressure gauge can be
provided with additional signs and safety markings advising on
special conditions:
• Advice on the filling liquid
• Advice on calibration
• Oil-can deleted (if oxygen is used)
837-2.
2.6 Safety equipment
This device is fitted with a (S3) solid front and rear wall (F6509)
or (S1) blow plug (F5509) according DIN 16003, capable of
being blown out. For the description, please refer to Chapter
5.3.4. The window uses multi-layer safety glass.
2.7 Environmental protection
This device may optionally contain a filling liquid (e.g. glycerin
or silicone oil). The provisions set out in the REACH regulation
on production and use of chemicals are to be respected, and
the relevant safety data sheets from the manufacturers of the
chemicals are available on our website for download. Electric
contacts are offered as a gauge option. The provisions set out
in the WEEE regulation EU directive 2012/19/EC on electrical
and electronically equipment are to be respected, and the
products are registered at the EAR under the number DE
26646349.
3 Technical data
The detailed technical information can be found in the
documents in the Appendix, Chapter 11.
4 Labeling on the device
The label with the serial number, type designation and process/
ambient temperature range is located on the outside of
the housing. The materials identifier is encoded in the type
designation.
2