9.2 Conduct in the event of faults
All defective of faulty devices must be taken out of service.
If a repair is required, the device must be sent directly to our
Repairs Department. We request that all returns of devices are
agreed with our Service Department.
9.3 Fault table
Possible situations indicating a fault:
• Jerky or random movement of the pointer
• Pointer does not set to zero for pressure less display
• Indications that the measurement system seal is imperfect
(discoloration to dial display or of filling liquid)
• Bent or loose pointer
• Cracked window
• Leaks when the device is filled
• Damage to housing
In these instances, replacement of the pressure gauge is
always required.
9.4 Conduct following fault rectification
See Chapter 8.3 Mounting/Installation

10 REMOVAL, DISPOSAL

10.1 Safety
Residues of measuring media in and on
removed gauges can constitute a risk to people,
the environment and equipment. Adequate
precautionary measures must be adopted.
If necessary, the devices must be cleaned
thoroughly (see advice in safety data sheets).
10.2 Removal
• When undertaking servicing work on the device, the pressure
lines must be depressurized, the electrical connections
isolated from the mains supply, and the plant secured against
being switched on again.
• Demount the gauge using a suitable tool
10.3 Disposal
Please help to protect the environment
and dispose of or recycle the devices and
components used in accordance with the
applicable regulations.
11 APPENDIX
11.1 Data sheet for Bourdon tube pressure gauge T5500,
T6500
Detailed data sheet is available from supplier's website (see 1.6
Manufacturer's address, customer services)
This table refers to specific documents:
Model Description
T5500 SS pressure gauge model T5500.
T6500 SS pressure gauge solid front model T6500.T5500-T6500
© Ashcroft Inc. 2018, 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0357, www.ashcroft.com
All sales subject to standard terms and conditions of sale. T5500-6500_gauge_im_RevB_(008-10263)_01-02-19
Document
T5500-T6500
5