dol sensors iDOL 20SCR Technical User Manual - Page 3
Browse online or download pdf Technical User Manual for Accessories dol sensors iDOL 20SCR. dol sensors iDOL 20SCR 4 pages. Capacitive sensor
If the max. current (Ie) is exceeded, the sensor will try to change from OFF to ON 6 times, at the same time as
quick pairwisered LED flashes occur.
4 User Guide
When there is material in front of the sensor, the output is in the reference position (OFF). When the material
disappears, the timer, starts, and the output will change to on after the set delay.
The status of the sensor is indicated with a red LED.
The sensor sensitivity and delayed disconnection can be adjusted via the SmartAdjust app.
ON
Sensor
LED
Contact
5 Maintenance
If the sensor is located in a particularly dirty environment, it may be necessary to clean the area around the
sensor.
Otherwise, no additional maintenance is required.
6 Technical data
Electrical
Rated voltage (Ue)
Frequency
Max. current (Ie)
Direct connection to Ue (current >>
500 mA) without damage to the
sensor
Min. ON current (Im)
OFF current (Ir)
Voltage drop (Out) (current > 20
mA)
Time delay, start-up
Time delay, ON (adjustable)
iDOL 20SCR
Delayed disconnection:
fixed delay or delay can be adjusted via the SmartAd-
just app.
Delayed connection:
OFF
fixed delay or delay can be adjusted via the SmartAd-
just app.
Sensitivity:
fixed distance or distance can be adjusted via the
ON
SmartAdjust app.
OFF
MaxRun-timer:
ON
iDOL 20 SCR adjustable 1-7200s via SmartAdjust app
OFF
V AC
V DC
Hz
mA
Times
mA RMS/DC
mA RMS/DC
mA RMS/DC
mA RMS/DC
mA
RMS/V DC
ms
s
www.dol-sensors.com
Technical User Guide
20 - 280
20 - 280
47 - 63
500
> 10
< 10 (Ue = 20 - 90)
< 4 (Ue = 90 - 280)
< 3 (Ue = 20 - 90)
< 1 (Ue = 90 - 280)
< 6
< 150
0 - 3600
3