6.2 Receiver's Front and Rear Panels
RS-232 OUT
STD UPDATE
1
2
STD/UPDATE: This switch is reserved for factory use only.
1
RS-232 OUT: Connect to a serial controllable device for the
2
extension of RS-232 signals.
POWER LED: This LED will illuminate to indicate the unit is on and
3
receiving power.
4
LINK LED: This LED will illuminate solid when both Transmitter and
Receiver are connected and communicating with each other
properly.
DC 48V: Plug the 48V DC power adapter into this port and connect
5
it to an AC wall outlet for power.
6
IR1 BLASTER: Connect to the supplied IR Blaster cable for IR signal
transmission. Place the IR Blaster in direct line-of-sight of the
equipment to be controlled.
IR2 EXTENDER: Connect to the supplied IR Extender cable for IR
7
signal reception. Ensure that remote being used is within the direct
line-of-sight of the IR Extender.
CAT5e/6/7 IN: Connect to a compatible HDBaseT Transmitter with
8
a single Cat.5e/6/7 cable for transmission of all data signals.
9
HDMI OUT: Connect to an HDMI TV, monitor or amplifier for digital
video and audio output.
POWER
LINK
3
4
IR1
BLASTER
IR2
DC 48V
EXTENDER
5
6
7
8
HDMI OUT
9