Page 3
The remote is set at the factory with all switches ON (UP), which causes the Cat.
No. 689 not to be associated with any projector. To program the Cat 689 to be
associated with projector 1, set DIP switch 1 OFF (DOWN), and leave the other
switches ON (UP). To program the Cat. No. 689 to be associated with projector 2,
set DIP switch 2 OFF (DOWN), and leave the other switches ON (UP).
When a Cat 689 is programmed to be associated with a projector, any format
selection from that remote will cause the CP500 to switch to that projector.
NOTE:
Mute and fader changes from any remote controller will not affect the projector selection.
Operation
The Cat. No. 689 is activated when the CP500 enters its Format Selection menu
"Current Format" and is disabled at all other places in the CP500 menu tree in
order to avoid unwanted activation of CP500 modes from the remote.
When the CP500 Current Format screen is active, the Cat. No. 689 is allowed to
control the CP500 in the same manner as the front panel keys on the CP500. The
eight format selection softkeys on the CP500 and their associated format-active
LEDs are repeated on the Cat 689's eight format selection switches and LEDs.
Both the CP500 fader and the Cat. No. 689 fader are simultaneously active, and the
7-segment fader displays on both devices reflect the current fader level. The mute