CYP CLUX-18EU Operation Manual - Page 9

Browse online or download pdf Operation Manual for Cables and connectors CYP CLUX-18EU. CYP CLUX-18EU 12 pages. 1 by 8 hdmi v1.3 splitter
Also for CYP CLUX-18EU: Operation Manual (12 pages)

6.2 Rear Panel

SERVICE ONLY
1
USB
1
For software update only.
HDMI OUT 5/6/7/8
2
HDMI equipped displays connected to these slots will display the
same content that is input from the HDMI IN slot.
SYS Reset ON/OFF
3
This switch allows user to perform a system reset. The default setting
is OFF, leave as is when in normal use. When switched ON, the unit
will perform a system reset every 8~10 minutes, in order to perform
this function the displays must have CEC support. When performed
successfully, the unit will automatically switch the displays to the
HDMI 1 input.
NOTE: For the system reset function to work will not affect displays
that are not CEC compatible.
EDID Control switch
4
This EDID control switch determines if you are going to use the
EDID from the display attached to output 1 or use an onboard
EDID. When TV is selected, the EDID will attach to output 1 and
will accept a 3D signal input to display on the 3D TV. When STD is
selected, the EDID will become onboard EDID. The factory default
setting is TV mode.
Power
5
Plug the 5 V DC power supply into the unit and connect the
adaptor to AC wall outlet.
2
3
4
2
5
4