DOLD BG 5913.08/ 1 Series Operating Instructions Manual - Page 8
Browse online or download pdf Operating Instructions Manual for I/O Systems DOLD BG 5913.08/ 1 Series. DOLD BG 5913.08/ 1 Series 20 pages. Multi-function safety system input module
Technical Data
Voltage Supply
Nominal voltage U
:
DC 24 V (coming from the basic module
N
BH5911)
Voltage range:
with max. 5% residual ripple: 0.85 ... 1.15 U
Nominal consumption:
max. 60mA
(no load on semiconductor outputs)
Short-circuit protection
of the modules:
internally with PTC
Input
Control voltage
via X1, X2, 48.58:
DC 23 V at U
Control voltage
via S12, S14, S22, S24,
S32, S34, S42, S44:
4.5 mA each at U
Minimum voltage
on S12, S14, S22, S24,
S32, S34, S42, S44:
DC 16 V
Semiconductor Outputs
Output at terminal 48 and 58: Transistor outputs, plus-connected
Output nominal voltage:
DC 24 V, max. 100 mA constant current,
max. 400 mA for 0.5 s
Internal short circuit, overtemperature, and
overload protection
Reaction Times (time till reaction of the assigned output):
Typ. NO time with U
:
N
Input modules
Manual start
BG 5913
Emergency stop
max. 80 ms
Light barriers
max. 80 ms
or simulation:
Safety gates
max. 80 ms
Two-hand control
max. 85 ms
Break time (reaction time):
Input modules
BG 5913
Emergency stop
max. 33 ms
Light barriers
max. 33 ms
Safety gates
max. 33 ms
Two-hand control
max. 33 ms
General Data
Operating mode:
Temperature range:
Clearance and creepage
distances
rated impulse voltage /
pollution degree:
EMC:
Radio interference
suppression:
Remark: This device is designed for industrial ambient conditions.
When used in other environment, it is possible that wire bound or
radiated interference occurs.
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
N
N
N
Automatic start
First start
Restart
max. 1 s
max. 115 ms
max. 1 s
max. 115 ms
Gate closing:
max. 115 ms
Continuous operation
± 0 ...+ 50 °C
At an operating temperature of 50 °C
the modules must be mounted with
a distance of 3 - 5 mm.
4 kV / 2 (basis insulation) IEC 60 664-1
IEC/EN 61 326-3-1, IEC/EN 62 061
Limit value class A
EN 55 011
IP 20
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplastic with V0 behavior
according to UL Subject 94
Amplitude 0.35 mm IEC/EN 60 068-2-6
Frequency 10...55 Hz,
Technical Data
Shock resistance
Acceleration:
Pulse duration:
Number of shocks:
Climate resistance:
Terminal designation:
Wire connection:
Wire fixing:
Mounting:
Weight:
Dimensions
Width x height x depth:
Standard Type
BG 5913.08/01MF0
Article number:
8
10 g
16 ms
1000 per axis on three axes
0 / 050/ 04
IEC/EN 60 068-1
EN 50 005
DIN 46 228-1/-2/-3/-4
Box terminal with wire protection, remov-
able terminal strips.
DIN rail
IEC/EN 60 715
193 g
22.5 x 84 x 121 mm
DC 24 V
0055530
BG 5913.08/_1 _ _ _ / 03.11.20 / 314A