Cloud 36-50 MULTI-ZONE Installation & Operation Manual - Page 4
Browse online or download pdf Installation & Operation Manual for Amplifier Cloud 36-50 MULTI-ZONE. Cloud 36-50 MULTI-ZONE 14 pages. 36/50 2 zone integrated mixer amplifier
36/50: Installation and Operation Manual
4
Installation
The Cloud 36/50 is suitable for mounting in a standard 19" equipment rack and occupies two
units of rack space. Sufficient ventilation should be provided particularly where the unit is
required to deliver a high output power for a long period of time. The cooling is provided by
convection and the airflow through the ventilation slots must not be obstructed. In rack
mounting applications we recommend that 1U of space is left both above and below the unit,
though this may not be necessary if other equipment directly above and below the unit does
not cover the ventilation slots. In free standing applications the feet supplied should be fitted,
the unit stood on a flat surface and precautions should be taken to ensure that items will not
be placed on top of the unit that may cover the ventilation slots. The 36/50 is 300mm deep
but a depth of 375mm should be allowed to clear connectors.
5
Music Inputs
The 36/50 operates in mono but is fitted with six stereo line inputs, which are internally mixed
to form mono signals. The line inputs are suitable for most music sources such as compact
disc players, tape players and receivers etc. All the inputs are unbalanced and use RCA type
phono sockets. The input impedance is 47kΩ.
6
Sensitivity & Gain Control
All six line inputs have a pre-set gain control on the rear panel adjacent to the respective
input sockets. The input sensitivity can be varied from -12dBu (195mV) to +8dBu (2.0V). The
pre-set gain controls should be set so that all the input signals operate at the same level
within the unit and the music level controls have an optimum range of control. For nominal
operating levels the figure below gives a rough guide to settings for
typical equipment, though as there is little in the way of standards
for the output levels of CD players, tape players etc It is likely that
some experimentation will be needed to find precisely the right
levels. When setting the gain controls to achieve the maximum
output level it should be noted that the unit has clip limiters on all the
power amplifier sections. These clip limiters can give a false
impression of the signal level, allowing the user to set the input gain
controls to inappropriately high levels without noticeable clipping.
7
Music Control - Local or Remote
The music source and music level
control functions can be controlled from
either the front panel, or a remote
control plate located up to 100m from
the 36/50. There are two remote
control plates available for the 36/50
the RSL-6 and the RL-1. The RSL-6
should be used when remote control of
music source and music level is
required whereas the RL-1 can be used
when the application calls for remote
control of the level only (source
selection via front panel). RSL-6 and
RL-1 remote control plates can be
mounted onto a standard British flush
or surface mounted 25mm deep back
box. Two-core cable with overall
screen should be used to connect the
remote controls to the Cloud 36/50, the
diagrams to the right show how to
connect the two remote plates.
See section 21 for installation details.
06/12/02 V5.0
Typical Gain Settings
3