Ashly NE 4200.25 Operating Manual - Page 9

Browse online or download pdf Operating Manual for Amplifier Ashly NE 4200.25. Ashly NE 4200.25 16 pages. Network enabled multi channel power amplifiers
Also for Ashly NE 4200.25: Operating Manual (16 pages)

Ashly NE 4200.25 Operating Manual
Operating Manual - NE Multi Channel Power Amplifier
WR-1 Remote Level Control - The WR-1 is a dual potentiometer remote volume control designed to fit in a standard
wall electrical box, and is wired to the amplifier (with or without DSP installed) back panel Euroblock connector labeled
"Remote Level Control" using four conductor wire. If wiring a custom potentiometer assembly other than the WR-1, connect
+5V from the Remote Level Control Euroblock connector to the potentiometer's CW pin, GND to the CCW pin, and the channel
under control to the wiper. Do not connect the WR-1 remote level control ground to any other external grounds.
WR-2 Remote Preset Recall Switches - The WR-2 al-
lows selection of one of four presets via interlocking pushbutton
switches. Each pushbutton switch can be connected to a Preset
Recall Pin on the back panel of the amplifier. The terminal num-
bers correspond to the first 4 Preset Memory locations in the
controlled amplifier. Pressing a button will select the correspond-
ing preset. Windows are provided by each switch for a user-
generated label.
9