P RO D UC T DATA
Input
Motor
VAC
Inrush
A(W)
220
2.86 (630)
230
2.99 (689)
240
3.13 (750)
M E CH A N I CA L
I N STA L L ATI ON :
Recommended wall opening for proud mounting: 360w x
›
431h x 112d
Position the unit into the prepared wall recess allowing a
›
6mm clearance all around the unit for packing and
adjustment.
Open door panel of dryer using key provided.
›
Remove and retain 2 cover screws from underside of internal
›
dryer casing, remove casing.
Provide supply wire in accordance to local wiring regulations
›
to hole location in rear of back box and attach securely to
chassis with suitable cable gland (May differ to that supplied)
Fit temporary screws into slots on side walls. Do not fully
›
tighten screws into wall to allow for horizontal adjustment.
Fix casing to surrounding structure using suitable screws. Pack
›
and adjust as necessary to ensure unit is square and level. Do
not over tighten screws or the unit casing may become
distorted. Remove temporary screws from slots.
Re-fit internal dryer casing and re-fit retained screws.
›
Close and lock door
›
3
02.4011 User Manual
Heater
Operating
Inrush/
A(W)
Operating A(W)
1.91 (420)
1.91 (420)
2.00 (459)
2.00 (459)
2.08 (500)
2.08 (500)
Total
Inrush
Operating
A(W)
A(W)
4.77 (1050)
3.82 (840)
4.99 (1148)
3.99 (918)
5.21 (1250)
4.17 (1000)
ELECTRI CAL
I NSTALLATI ON:
s
WA RN I N G
!
Disconnect power at the service breaker before installation
›
or servicing
A qualified electrician must install this product. It is
›
recommended that this unit be checked every 6 months
All units must be supplied with a 3-wire service. The earth
›
wire must be connected to the dryer's back plate
The means of disconnection must be in the fixed wiring in
›
accordance with the correct electrical regulations
s
DAN GE R
!
Failure to properly ground unit could result in severe
›
electrical shock and/or death.
Open door panel with suction cup provided.
›
Door is right hand hinged.
Remove and retain 2 cover screws from underside of internal
›
dryer casing, remove casing
Provide supply wire in accordance to local wiring regulations
›
through suitable cable gland (May differ to that supplied) in
rear and attach securely to chassis
The hand dryer must be supplied from the mains (220-240
›
volt supply) via a suitably rated double pole isolation switch
with at least 3mm air gap in each pole.
Connect supply and ground wires to terminal block where
›
indicated or connect supply wires to terminal block where
indicated and connect ground wire to base with ground
screw
Re-fit internal dryer casing and re-fit retained screws
›
(Do not overtighten)
Close door
›
www.dolphinsolutions.co.uk