Cytech KP04 Installation Manual - Page 6

Browse online or download pdf Installation Manual for Keypad Cytech KP04. Cytech KP04 20 pages. Lcd keypad
Also for Cytech KP04: Quick Start Manual (4 pages)

KP04 LCD Keypad Installation Manual
the Keypads can be used. However, each wire pair (KA/KB, MIC/Voice,
12V/COM) is reversed when connecting to the terminal blocks. This change
was decided to standardize the connections for all Comfort terminals (Main,
UCM, Slave Keypads etc).
For Comfort I, firmware should be Outside (PRO) or Action (ULTRA) 4.226
or above. The firmware can be upgraded by purchasing the IC01-OUT or
IC01-ACT and replacing the U1 IC on Comfort. The KP04 cannot be used
with Comfort ENTRY. All Comfort II firmware versions are compatible with
KP04
A notable difference between the KP04 and KP01/KP02 is the volume control
increases the volume in the downward position, corresponding to the normal
direction of radios and other audio equipment.

Specifications

Dimensions: 89 (W) x 160 (H) x 31 (D) mm
Weight: 177 g
Power Supply: 12V DC from Comfort System
Current Consumption: 50 mA idle (without voice)
Comfort IR codes received: 0 to 127

System Requirements

Comfort system with firmware version "Outside or Action 4.226" and
above. Comfort ENTRY systems cannot be used with the KP04
UCM01 with firmware version "UCM5.72" and above for
downloading programmed vocabulary.

Contents

The KP04 LCD Keypad package consists of the following*:
KP04 Keypad
KP04 Manual (this booklet)
2 wall plugs and screws for mounting.
3 x 2 way removable terminal blocks
*Subject to changes without prior notice

Set-Up

Connections

JP1 – 12V/COM connector. Connected to 12V/COM on Comfort.
JP2 – KA/KB connector. Connected to KA/KB on Comfort.
JP3 – VOICE/MIC connector. Connected to VOICE/MIC on Comfort.