Fig. 5: Controls on E9
controller module
Fig. 6: E9 isobar diagrams
E9 Manual

Operation with P1200A

Up to two E9 cabinets can be driven by each P1200A power amplifier
channel fitted with an E9 controller module.
Fitting one E9 and one subwoofer controller module allows a single
mainframe to drive two E9 cabinets and two active subwoofer cabinets.
All cabinets can be linked together locally and fed by a single 4-wire
cable from either mainframe output connector.
The CUT setting is available. The characteristics of the CUT setting are
explained in the previous section
Controller settings".
Standard setting
If neither the CUT switch nor the BX switch is selected, the module is
configured for use with E9 cabinets as stand alone system without any
subwoofers.
BX switch and indicator
When the E9 is used with the passive E15-BX subwoofer, i.e. E9 and
E15-BX are linked to the same amplifier output, the BX switch should be
selected. The LF level - boosted by the bass extension cabinet - is then
attenuated by 3 dB, thereby increasing headroom at bass frequencies.
SUB (CUT and BX both selected)
Selecting the CUT and BX switches activates a lowpass filter. The module
now transmits frequencies from 50 to 110 Hz only, allowing the d&b
E15-BX to be driven as an active subwoofer.
Important: The E9 controller module drives EP5 pins 1/2 (NL4: pins
1+/1–). Therefore the SUB setting is not suitable for driving d&b active
subwoofer cabinets.

Dispersion characteristics

The diagrams below show dispersion angle vs frequency plotted using
lines of equal sound pressure (isobars) at –6 dB and –12 dB. The
nominal 90° horizontal dispersion is maintained from 20 kHz down to
900 Hz.
(3.1 EN)
"Operation with D6 or D12 -