SAFETY INFORMATION
UV WARNING
Warning:
Exposure to direct LED UV light may be harmfull.
Warning:
Always protect eyes and skin from UV LEDs.
Warning:
Never look directly into UV LEDs during operation.
Warning:
Disconnect before servicing.
Warning:
After installation, all UV light should remain internal within the casing.
Warning:
Ensure no UV light is visible from outside the casing.
Warning:
High intensity ultraviolet light.
Warning:
All LED lifepans can vary, for optimisation replace LED's EVERY 12 MOTNHS.
ELECTRICAL WARNING
Warning:
The appliance must be installed in accordance with national wiring regulations.
Warning:
Mains power supply must be isolated prior to carrying out any electrical work.
All-pole disconnection from mains must be incorporated in the fixed wiring.
Warning:
The supply cord cannot be replaced. If damaged the appliance must be replaced.
Warning:
The external accessories must be used only with the appliance provided by
the manufacturer.
Warning:
The power supply mains system must be provided with an 'all-pole disconnection'
device connected directly to the supply terminal that providing a full disconnection
under overcoltage category III.
Warning:
This appliance requires no maintenance.
Warning:
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved.
Warning:
Children shall not play with the appliance.
IN THE BOX
4
1.
LED Split Connector
2.
500mm Extension Cable
3.
1000mm UV-c LED Strip
4.
Storefront Protector Sticker
INSTALLATION
STEP 1
Isolate the power to the AC unit
STEP 3
On the output side of the BlueScience LED Driver, connect the LED Split Connector
STEP 4
Connect 700mm UV-c LED Strip
and 1000mm UV-c LED Strip to
the LED Split connector.
(Use extension cables if required.)
STEP 5
Connect the UV-c LED strip and add date of
installation to the tag. Note: it is important for
you or any other Engineers to be able to identify
the age of the UV-c LED!
STEP 6
1
2
3
Lay the UV-c LED Strip on the top of the drip tray, making sure the UV-c LED's are facing in towards
the unit. UV-c LED's must not radiate out or point out in the direction of the room.
STEP 2
Remove the Cover
STEP 7
If required, UV-c LED Strip can be cut to a desired
length. Cuts can only be made at the terminal point
seen after each UVC LED labelled 'LED 3', peel back
the adhesive strip and fix the UV-c LED strip into place.
STEP 8
STEP 9
Ensuring the filter door is shut, switch power back on and run
AC unit. Protective eyewear and skin coverings are required
Refit cover
from this point.
STEP 10
5
4
Using a UVC Meter at a distance of
300mm check in 6 places for readings.
Once a zero reading has been recorded
around the unit protective eyewear and
clothing can be removed.
STEP 11
Apply BlueScience seal to the unit –
to ensure the safety of fellow Engineers.
STEP 12
Apply storefront protector window sticker
at the main entrance of the building.
UV
LIGHT
6
3
NEUTRALISES
KILLS
VIRUSES
ODOURS