Electrical wiring
The electrical supply to the heater must be
230V50Hz fused at 5A. The absorbed power
of each model is specified on the electrical
wiring label. For cable sizing information
refer to the information detailed in the table
below.
Absorbed electrical power
Type
Absorbed power
W
Absorbed current
A
Oil burner
W
Heater protection
Electric board protect
Fuse
Flue connection
This warm air heater is a type B23 appliance
intended to be connected to a flue which
discharges the products of combustion to
the outside of the room containing the
appliance. The combustion air is drawn
directly from the building. The appliance
does not have a draft diverter and
incorporates a fan upstream of the
combustion chamber/heat exchanger.
8
OFSU32
OFSU40
330
700
1.7
1.9
300
300
OFSU70
OFSU100
660
1360
3.4
5.3
400
500
IP20
IP44
10 Amp