Asko TD40 Service Manual - Page 10
Browse online or download pdf Service Manual for Dryer Asko TD40. Asko TD40 10 pages.
COMPONENTS AND MEASURED VALUES
MOISTURE SENSOR
Art. no. 80 618 55
The moisture sensor is used to control the
drying process. During operation the sensor
must have an output signal of between 1 – 16
m VDC. Other values will cause the program
to be interrupted.
DOOR SWITCH
Art. no. 80 531 07
The front door activates a door switch which
interrupts the program in the open position. If
the door has been opened and closed in the
course of the program the machine must be
restarted with the start button.
INTERIOR LIGHTING
Art. no. 80 618 62
Interior lighting. N.B. 10 W, controlled by the
door switch.
BUZZER
Art. no.
80 618 83
The buzzer indicates program end with an
acoustic signal.
OVER FLOW PROTECTION
(CONDENSATION MACHINES)
Art. no.
80 526 43
If both tanks of the tumbler are overfilled, the
program is interrupted by means of a switch
mounted on the lower tank. Over flow is
indicated on the display.
PROGRAM CONTROL (TD30/40/33A/44A)
Art. no.:
80 650 42
The control unit contains microprocessors for
controlling programs, motor, elements etc.
gram, motor, element m.
PANEL CARD
The display contains pushbuttons and indica-
tions.
TD30/40 (Small display) LED
Art. no.
80 642 60 ASKO
Art. no.
80 644 71 OEM
HEATING ELEMENT
TD 11/22/30 (US)/33A (US)/40/44A
Art. no.
80 638 08 (2500 W)
Art.no. 80 800 75 Rev. 1