Asko TD73 User Instructions - Page 11

Browse online or download pdf User Instructions for Dryer Asko TD73. Asko TD73 16 pages. Tumble dryers

Signal lamp
The signal lamp indicates that the main switch is "on".
Driving motor
The driving motor is a bi-polar unit with direct-coupling fan and gear facility
for driving the drum.
Capacitor
The capacitor is 8 uF mounted on the component bridge.
Heating element
The heating element with 1900 + 950 W output is the spiral type.
Contactor and starter relay
The contactor and starter relay are located on the component bridge. The starter
relay breaks contact when there is overheating and when the door is opened.
Door contact
The door contact is activated by the door, and breaks the operating circuit.
Condensate water pump
There is a pump in the machine to pump water from the lower container to a
container in the panel.
Overflow protection
If both the water containers become full, a level switch on the lower container
stops the program. It is controlled by a micro switch fitted on the lower container.
Internal cables
Internal cables are 0,75 or 1,5 mm
2
and 1,0 mm
2
for earth wire.
Connecting cables
2
The connecting cables shall be RKK 3, 4 or 5x1,5mm
Wiring diagrams
Wiring diagrams with timer diagrams and cable layout are incorporated in the
machines.
TD 76