17) Set reflector housing into the swivel sockets with the light pointed down and carefully
engage the gear rack. (make sure the drain hole and serial number is facing down).
18) Form the loops in the bulb wires in the same shape as the ones removed. (looking into the
back, the gear-toothed rack is on the right and the smooth arch is on the left). The wires on
the left are formed sharply down and back of the bulb assembly, then a 1" diameter loop is
formed back up and toward the smooth arch, continuing around to pass through the
partition below the lever switch.
The bulb wires on the right side are formed sharply up and back at the back of the bulb
assembly, then a 1" diameter loop is formed on the gear side and continued to pass through
the partition wall above the lever switch. These loops allow the elevation movements and
must not interfere with the lever switches or touch the reflector.
19) When the bulbs are properly installed to this point, you will have one long wire and one
short wire for each bulb.
20) The short wire of the left bulb and the long wire of the right bulb are joined together and
inserted into the lower left hole of the terminal block and screw tightened securely.
21) The short wire of the right bulb and the long wire of the left bulb are joined together and
inserted into the upper right side hole of the terminal block and screw tightened securely.
Gather wires together and install new cable ties. (see Figure 19)
22) Replace the top cover carefully, making sure the partition is seated in its proper groove and
the screw holes at the front match the metal braces.
23) Reinstall the four (4) long cover screws starting from the back and work forward, then
install the four (2) top screws at each side (total of 4). Tighten all screws securely, taking
care not to overtighten.
24) Light assembly is ready to be reinstalled on mount. Reattach control cable and wire power
leads. Precautions should be taken to make power connections as water tight as possible.
FIGURE 8
9
FIGURE 9
Y1-03-0158 Rev. D