Ambient Weather WH117L User Manual - Page 17
Browse online or download pdf User Manual for Weather Station Ambient Weather WH117L. Ambient Weather WH117L 20 pages.
Accuracy
HectoPascals (hPa)
Hygrometer
Inches of Mercury (inHg)
Range
Relative Barometric
Pressure
6 Specifications
6.1 Wireless Specifications
Line of sight wireless transmission (in open air): 300 feet
Frequency: 433.92 MHz
Update Rate: 48 seconds
6.2 Measurement Specifications
The following table provides specifications for the measured parameters.
Measurement
Indoor Temperature
Outdoor Temperature
Indoor Humidity
Outdoor Humidity
Barometric Pressure
6.3 Power Consumption
Base station : 3 x AA 1.5V Alkaline batteries
Remote sensor : 2 x AAA 1.5V Alkaline batteries
Battery life: Minimum 12 months for base station
Minimum 24 months for thermometer-hygrometer sensor (use lithium batteries in cold
weather climates)
7 Troubleshooting Guide
Problem
Wireless remote (thermo-hygrometer) not
reporting in to console.
Version 2.1
©Copyright 2015,
Accuracy is defined as the ability of a measurement to match the actual
value of the quantity being measured.
Pressure units in SI (international system) units of measurement. Same
as millibars (1 hPa = 1 mbar)
A hygrometer is a device that measures relative humidity. Relative
humidity is a term used to describe the amount or percentage of water
vapor that exists in air.
Pressure in Imperial units of measure.
1 inch of mercury = 33.86 millibars
Range is defined as the amount or extent a value can be measured.
Measured barometric pressure relative to your location or ambient
conditions.
Range
32 to 140 °F
-40 to 149 °F
1 to 99 %
1 to 99%
8.85 to 32.50 inHg
Solution
Accuracy
± 2 °F
± 2 °F
± 5% (only guaranteed
between 20 to 90%)
± 5% (only guaranteed
between 20 to 90%)
± 0.08 inHg (within
range of 27.13 to 32.50
inHg)
1. Resync the unit. Press and hold the + key for
10 seconds to resynchronize. The remote sensor
search icon
Page 17
Resolution
0.1 °F
0.1 °F
1 %
1 %
0.01 inHg