Ambient Weather WS-1170 User Manual - Page 5
Browse online or download pdf User Manual for Weather Station Ambient Weather WS-1170. Ambient Weather WS-1170 16 pages. Advanced weather station
2.4.3 Sensor Operation Verification
Verify the indoor and outdoor humidity match closely with the console and sensor array in the same
location (about 10' apart). The sensors should be within 8% (the accuracy is ± 4%). Allow about 30
minutes for both sensors to stabilize.
Verify the indoor and outdoor temperature match closely with the console and sensor array in the same
location (about 10' apart). The sensors should be within 4°F (the accuracy is ± 2°F). Allow about 30
minutes for both sensors to stabilize.
3. Remote Sensor Installation
It is recommended you mount the remote sensor on a north facing wall, in a shaded area. Direct
sunlight and radiant heat sources will result in inaccurate temperature readings. Although the sensor is
water resistant, it is best to mount in a well protected area, such as an eve.
Use 3 screws to affix the mounting bracket to the wall with a precision scewdriver. Connect the
remote sensor to the wall bracket.
4. Console Operation
Note: The console has four keys for easy operation: SET key, ALARM key, MIN/MAX key and
+
key. There are four program modes: Quick Display Mode, Set Mode, Alarm Mode and Min/Max
Mode.
Any program mode can be exited at any time by either pressing the SNOOZE/LIGHT key, or waiting
for the 10-second time-out to take effect (the snooze/light key is on the top of the unit and is labeled
SNOOZE/LIGHT).
4.1 Quick Display Mode
While in Normal Mode, press the SET key to enter the Quick Display Mode as follows (once for
outdoor temperature and dew point and twice for absolute pressure and relative pressure):
1.
Display Outdoor Temperature and Dew Point. Press the MIN/MAX or
between outdoor temperature and dew point.
Version 1.4
©Copyright 2010, Ambient LLC. All Rights Reserved.
Figure 3
+
key to toggle
Page 5