Ambient Weather WS-HE01 Manual - Page 5

Browse online or download pdf Manual for Measuring Instruments Ambient Weather WS-HE01. Ambient Weather WS-HE01 9 pages. Heat index monitor with temperature, humidity, dew point user manual

Ambient Weather WS-HE01 Manual

2.1 Set Mode

To set the time and units of measure, press and hold the SET button 3 seconds or longer, and let go of
the SET button.
1. 12/24 Hour. 12 Hr or 24 hour will begin flashing. Press the + button to switch between 12
hour and 24 hour display mode. Press the SET button (do not hold) to advance to the next
setting.
2. Hour of Day. The hour of day will begin flashing. Press the + button to increase the hour, and
the ALARM button to decrease the hour. Press the SET button (do not hold) to advance to
the next setting.
3. Minute of Day. The minute of day will begin flashing. Press the + button to increase the
minute, and the ALARM button to decrease the minute. Press the SET button (do not hold)
to advance to the next setting.
4. Temperature Units of Measure. The °F or °C icon will begin flashing. Press the + button to
switch between °F and °C. Press the SET button (do not hold) to exist the Set Mode.

2.2 Heat Index Alarm Set Mode

To set the Heat Index Alarm, press and hold the ALARM button for 3 seconds or greater, and the heat
index alarm set point will begin flashing. To increase the Heat Index alarm set point, press the +
button. To increase rapidly, press and hold the + button. To decrease the Heat Index alarm set point,
press the ALARM button. To decrease rapidly, press and hold the ALARM button.
To confirm the Alarm setting and return to normal mode, press the SET button (do not hold).

2.3 Heat Index Alarm

To turn on the Heat Index Alarm, press (do not hold) the ALARM button. The alarm icon
appear. To turn off the alarm, press the ALARM button again, and the alarm icon will disappear.

2.4 Temperature, Heat Index and Dew Point Display

Press the SET button (do not hold) to switch the display between temperature, heat index and dew
point, or:

2.5 Calibration Adjustment Mode

The purpose of calibration is to fine tune or correct for any sensor error associated with the devices
margin of error. The measurement can be adjusted from the console to calibrate to a known source.
Calibration is only useful if you have a known calibrated source you can compare it against, and is
optional. This section discusses practices, procedures and sources for sensor calibration to reduce
manufacturing and degradation errors. Do not compare your readings obtained from sources such as
the internet, radio, television or newspapers. The purpose of the heat index monitor is to measure
conditions of your surroundings, which vary significantly from location to location.
To calibrate temperature and humidity, press and hold the SET button for 9 seconds and the
temperature will start flashing.
1. Temperature Calibration. To increase the temperature to match your calibration source,
press the + button. To increase rapidly, press and hold the + button. To decrease the
temperature, press the ALARM button. To decrease rapidly, press and hold the ALARM
button.
Version 1.0
©Copyright 2012, Ambient LLC. All Rights Reserved.
temperatureheat indexdew point temperature
will
Page 5