Ambirad Sorrento SOR 15 Instruction Manual - Page 10

Browse online or download pdf Instruction Manual for Heater Ambirad Sorrento SOR 15. Ambirad Sorrento SOR 15 20 pages. Quartz glow instant infra-red heaters

Ambirad Sorrento SOR 15 Instruction Manual
2. Use a minimum of 1.0mm2 H05RN-F supply
cable with 2 poles and earth and sleeve with
silicon glass fibre braided (250°C) sleeving.
The live and neutral wires must be
connected to the terminal block. See below.
3. The green/yellow wire should be connected
to the clamp marked with the earth symbol
using a suitable wire terminal. Fit cord grip
and terminal box saddle once wired.
4. Tighten the barrel nut of the compression
gland so that the
cable.
5. To prevent water
ingress, ensure that
the cover is secured
well
by
hand
tightening
all
screws evenly.

1.4.4 Titan range:

• Warning – this appliance must be earthed.
• The Titan series heaters are fitted with 3.0
metres of supply cable and a moulded 13A
plug therefore it is unnecessary to remove
the terminal cover plate in order to carry out
normal installation of this model.
rubber seal grips the
for