Ambirad TORNADO Installation And Operating Manual - Page 16
Browse online or download pdf Installation And Operating Manual for Heater Ambirad TORNADO. Ambirad TORNADO 16 pages. Gas fired mobile heater
Also for Ambirad TORNADO: Instruction Manual (8 pages)
User & Operating Instructions.
Ensure that you have read all other detail
included in these instructions prior to following
the operating instructions detailed below.
The heater can be operated on either a 110 or
230 volt electrical supply by inserting a suitable
connector/lead into either the 110 or 230 volt
appliance connectors.
Plug the supply lead into the connector on the
rear of the product.
Select the appropriate voltage.
Uncoil the hose from around the rear ring.
Attach the regulator to the gas bottle using the
spanner provided. Note Left hand thread.
Check for any gas leaks with soapy liquid
solution .
Ensure the hose is not twisted or damaged and
that the gas bottle is positioned at the side of the
unit to avoid heating at the outlet.
Note When positioning the heater please ensure
that all inlets and outlets are unrestricted there
are no combustible materials in the vicinity.
Please ensure the heated air is not directed
towards the gas bottle.
The temperature of the building can be
controlled using an optional remote thermostat.
Select remote thermostat. Plug the remote stat
lead into the remote stat socket.
After switching on the mains supply, ignition is
controlled
by
the
incorporated on the burner assembly.
Firstly you will hear the combustion and
convection fans running. ( Note - If the
combustion fan does not operate, then check to
Patented under European patent number 1561074
AmbiRad Limited Fens Pool Avenue
Brierley Hill West Midlands DY5 1QA
United Kingdom.
Telephone 01384 489700
Facsimile 01384 489707
Email
Website
Technical Suport
automatic
ignition
www.ambirad.co.uk
www.s-i-d.co.uk
see if the overheat stat reset has tripped. This is
located behind the combustion fan access
door - see 7.3)
After a delay of 15-20 seconds, you will hear a
'Clicking' noise, as the igniter assembly attempts
to light the gas. On ignition the amber light will
illuminate. If ignition does not occur then the light
turns off indicating there is potentially air in the
gas line.
Re-ignition can be attempted by restarting the
appliance. If ignition still does not occur and the
lockout lamp illuminates, it is likely that the low
gas pressure switch is activated indicating that
the LPG bottles are exhausted of gas and
require changing. If after changing the gas
bottles and ignition still cannot be achieved,
please refer to section 8.1 Fault Finding.
Note Connecting and disconnecting cylinders
MUST take place in a flame free atmosphere.
When the appliance is not going to be used for a
period of time the unit MUST be disconnected
from the electrical mains and gas cylinder.
When heating is complete, turn OFF the gas
supply. Leave the electric supply turned ON to
enable the combustion fan to operate for 10
minutes to cool the product prior to moving.
After cooling is complete, switch the 3 position
rocker switch on the rear of the product to the
OFF position and disconnect from the electric
supply and remove the electrical connector.
Disconnect the gas supply and recoil the hose
around the rear ring assembly.
unit
Note If the appliance is not to be used for a
period of time, ensure that the appliance is
stored in a dry environment.
AmbiRad is a registered trademark of AmbiRad Limited. Because of continuous product
innovation, AmbiRad reserve the right to change product specification without due notice