AMC MOUSE 01 Handmatig - Pagina 4

Blader online of download pdf Handmatig voor {categorie_naam} AMC MOUSE 01. AMC MOUSE 01 7 pagina's. Dual element digital motion detector (dual pyro element + microwave + anti-masking)
Ook voor AMC MOUSE 01: Installatie (4 pagina's)

AMC MOUSE 01 Handmatig
DIP 2
Alarm memory function
DIP 3
DUO-MASK function
3. The „tamper disable" jumper
If the tamper indicating enclosure opening will be used in addition to the tamper indicating detachment from
the wall, remove the JP jumper.
Turning off the microwaves – an example of use of the function.
The use of dual element detectors, especially when using the PIR and MW detectors in the
„AND" mode (alarm by both detectors in case of intruder detection), allows to reduce to a minimum the
amount of false alarms.
However, long-term exposure to microwave radiation is harmful to health, and therefore the MOUSE 01
has a feature to block the microwave detector when the Intrusion Detection System is disarmed.
The diagram of connecting the sensor to the control panel with a brief description of the implementation
of this feature is shown below.
The diagram of connecting the MOUSE 01 detector to the control panel to use the locking function of
The OUT3 output of the control panel is programmed as the power supply output (+12V), while the OUT5
output is programmed as the standby indicator.
The "B / S" control input, which is shorted to ground, is used to control the detector.
ON
The alarm memory function activation. This feature enables
quick
This is indicated by slow flashing LEDs. The LED color indicates
which
Red LED - – the alarm is generated by both PIR and WM
detectors. Green LED – alarm by microwave detector (OR
configuration. only).
Orange LED – alarm by PIR detector (OR configuration. only).
This function is implemented by the B/S terminal.
The configuration is the same as for the MW detector.
The alarm memory is reset each time the control panel is armed.
OFF
Turning off the alarm memory.
ON
Switching on the DUO-MASK function. This is a special feature
allowing to determine when infrared or microwave is masked.
The alarm is generated after four-detections of the MW or PIR
detector within 40 seconds after the first activation. After this
time, the detector is zeroed.
OFF
The detector operates in the AND mode. The alarm is generated
by both PIR and WM detectors in case of intruder detection.
microwave detector and the alarm memory function.
determining
which
detector
detector
triggered
triggered
the
the
alarm.
alarm.
4