amc VIBRO AV ACQUISITION 4001 Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} amc VIBRO AV ACQUISITION 4001. amc VIBRO AV ACQUISITION 4001 11 pagina's. 4-channel data acquisition module with gain

9. Using the AVA 4001 module in DASYLab® 16
After running properly configured DASYLab® software the analog inputs will
be available to the user. The inputs are listed in the following tab: Modules >
Inputs/Outputs > MCC-DRV. The in AVA 4001 module only 4 analog inputs are
available, while remaining 4 analog inputs, the outputs and the counters are not
available.
To use an analog input, just drag it inside the worksheet (or you may double-
click it and indicate the module's position on the worksheet). A window will
appear as shown in the figure below. Mark All Channel 0..7 and confirm your
choice by clicking the OK button.
1.
You can enter your own module name in the Module name
field and provide a short description in the Description field.
2.
It is possible to activate analog inputs in this area. The
symbol with disconnected blue sockets stands for an
inactive input. A double-click on the symbol activates the
corresponding input and switches the symbol to connected
sockets with a lightning.
A single click on the active input changes its color from red
to green. The changes of settings, which are explained in the
following points, refer to the input marked in this way.
The next figure presents a situation, in which four input channels are active, while the first is marked
for editing settings.
If necessary, an input can be deactivated by double right-clicking the icon of the active input.
Attention
In AVA 4001 module, inputs 4 - 7 are not used. Activating them will reduce the maximum available
sampling frequency.
9
The user can configure the number of active
analog inputs, measurement range separately for each channel as well
as the sampling frequency.
Double-clicking the analog input window on the worksheet opens the
window shown below. This window needs to be discussed in detail, as
it gives the user the option to configure the AVA module parameters
for operation in DASYLab. The following areas can be distinguished:
AV ACQUISITION 4001 / ©AMC VIBRO Sp. z o.o.