Amcor ALD-1 2 Gebruikershandleiding - Pagina 6

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Amcor ALD-1 2. Amcor ALD-1 2 9 pagina's. Amcor inc. portable air conditioner owner's manual ald-12,000e, ald-1 2,000eh

Amcor ALD-1 2 Gebruikershandleiding

Before Use

Important!
• Transport the unit in an upright position only, or leave it in an upright position
for at least 2 hours before first use.
• Always place the unit on an even surface (Figure 1).
• The power cord is UL listed. It has a built-in
L.C.D.I. (Leakage, Current, Detection, Interruption)
circuit breaker for added safety.
If the power supply is interrupted, press the reset
button to reconnect the unit to the power source.
• Make sure the unit is connected to a correctly grounded power supply
(refer to the rating label located at the back of the unit).
• An opening in a window or wall is required to accommodate
the exhaust hose (kit supplied) to expel the warm air.
• Do not cover or obstruct the appliance inlet or outlet grilles (Figure 2).
• To avoid the risk of shock, the product should never be used
in bathrooms, shower rooms or in any other steamy or wet areas.
• The unit will cool when the room temperature is between
64°F and 110°F depending on the thermostat setting.
• Do not sit or place objects on the unit.
• Do not touch the unit with wet/damp hands or when standing barefoot.
• Avoid all contact with chemical based materials.
• The filter must be used with the product at all times.
When removing for cleaning, always disconnect the unit from the mains first.
• Turn off the appliance when not in use.
• At the end of each season all water must be drained and the unit and filters cleaned before storage.
• Drainage of the water container is required before moving the unit or
putting it into storage.
• If the electric socket is different from the plug provided, have a professionally qualified electrician
replace the plug with a suitable one. Avoid the use of adaptor plugs, multiple sockets and/or extension
leads; if their use is necessary, ensure that they conform to the current safety regulations.
• Do not pull the supply cable or place it near a source of heat; always unroll it completely
to avoid the possibility of dangerous overheating.
• If the supply cord is damaged, it must be replaced by the service agent or a similarly qualified person.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.
4
Operation - Electronic Control Models
Setting The Fan Speed
Press the SPEED button to choose the fan speed you require, high or low. The indicator of high
or low fan will light up at the same time.
If the unit is in AUTO mode, it will select the fan speed automatically according to the
ambient temperature (the related indicators, cool, fan or heat will light up), at this time the
fan speed switch is invalid.
Setting the Timer
Press the TIMER button to set the operating hours you desire (1 to 1 2 hours, the timer
indicator will light up). When the set time has elapsed, the machine will turn off
automatically. The display window will show the hour(s) you set as you press the TIMER button.
If the timer button is not pressed, the unit will work continuously.
By pressing the timer button but without turning on the unit, you can PRE-SET the time for
the machine to work. For example, if you press the timer to '2',
the unit will come on automatically after 2 hours.
All the above functions can also be performed with the supplied remote
control. This remote control requires 2 AAA batteries to operate.
Regulating the airflow direction
Turn the roller on the air vent to control
the airflow direction from the vertical louvres.
IMPORTANT!
• The compressor will start approximately 3 minutes after the unit is turned on (this will
help prolong the life of the compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.
• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps
working at the set level. If the ambient temperature rises above the chosen temperature +/ - 5°F,
the cooling will resume.
• In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set
(the fan keeps working at the set level). When the room temperature drops 5°F below the chosen
temperature, heating will resume.
• This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function
during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs,
wait for heating to resume.
• As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.
Move the air vent directly to adjust the
airflow direction from the horizontal louvres.
9