Sleep mode
The sleep mode function adjusts the set temperature of the unit to the thermal needs of
the body falling asleep as follow:
• Default fan speed: LOW
• Press the
-button to operate the sleep mode. Press the
cancel the sleep mode.
The set temperature will increase 1°C after 1 hour and a further 1°C after 2 hours.
• No FAN mode under SLEEP mode operation.
Dehumidification
If the unit will be used mainly as a dehumidifier just let the warm air return in the room.
Continuous drainage (see separate chapter) is then necessary and more efficient.
AIR FILTER
This air conditioner is equipped with two filter sets:
1. A multi layer filter in the upper air inlet, to clean the circulated room air, which
a. A screen filter, to remove dust particles.
b. An active carbon filter, to remove odours.
c. 3M Filtrete™ filter; to remove unhealthy particles from the air such as pollen, bacteria, animal
dander and dust. Selected models have the 3M Filtrete™ filter as standard. However, if you
require to add this to your model, or wish to purchase a replacement, call Amcor for details.
2. A screen filter in the lower air inlet, to remove dust particles.
NOTE! The active carbon filter and the 3M Filtrete™ filter are delivered in a plastic packaging. Don't
forget to install these filters. These filters take away unhealthy particles out of the room environment.
The filter holder on the rear of the unit can be opened. The active carbon filter and 3M Filtrete™
filter can be installed or removed. The screen filter is part of the filter holder ( see illustration).
Cleaning the air filters
a. The screen filters in the upper and lower air inlet should be cleaned regularly by rinsing
them under running water.
b. The positive/negative electrostatically charged 3M Filtrete™ filter is recommended to be
changed every 3 months. Unusual dirt, construction work, pets, the presence of smoke
and running the air conditioning unit continuously can shorten the life time of the 3M
Filtrete™ filter.
c. The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be
changed at the same time as the 3M Filtrete™ filter.
F
ilter installation
1
• Slide out the filter holder from the unit.
• Separate the filter fixer from the filter holder (see fig. 1).
8 8
2
-button again in order to
3
includes:
4