Amcor MD250 Gebruiksaanwijzing - Pagina 3

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Amcor MD250. Amcor MD250 6 pagina's. Mini dehumidifier
Ook voor Amcor MD250: Gebruikershandleiding (6 pagina's)

Amcor MD250 Gebruiksaanwijzing

IMPORTANT SAFETY INSTRUCTIONS

Before any installation, use and maintenance operation, read the safety instructions in
this manual carefully.
Remove all packaging materials from the unit, keep it away from babies and small
children to avoid the danger of suffocation.
Before inserting the plug make sure that the voltage is within the range indicated on
the rating label on the adapter.
The MD250 is intended exclusively for the use for which it was created, Amcor is not
responsible for any damage caused by improper use.
The MD250 is safe. However, as with other electrical appliances, use it with care.
Do not clean the MD250 by spraying it or immersing it in water.
Disconnect the product from the electrical outlet before cleaning the unit or its
components.
Do not connect the MD250 to an electrical outlet using an extension cord. If there is no
accessible outlet, a licensed electrician should install one.
When not in use, store out of reach of children.
Warning
Any service, other than regular cleaning should be performed by an authorised service
representative. Failure to do so could result in loss of warranty.
If the supply cord becomes damaged, it must be replaced by the manufacturer or by
its service agent or similarly qualified person in order to avoid a hazard. Use only the
supplied adapter.
POSITIONING
Ideal for small bedroom, wardrobe, storage, cloaks or shoe cupboard – wherever you
may want to keep dry or remove local dampness.
Danger
Do not use this unit in a bathroom or shower. Do not drip water onto the adapter or
dehumidifier.
Ensure that the filter and front vents are clean and not obstructed so air can circulate
freely through the unit.

HOW IT WORKS

Simple explanation of the Peltier effect (see picture on page 11).
Current passing through two dissimilar metals or semiconductors that are connected to
each other at two junctions creates a heat difference between these junctions. In other
words: one junction cools off while the other heats up.
The cold side is used to condensate the moisture from the air in the MD250
dehumidifier.
A Peltier device has no moving parts making it very reliable and silent.
ENGLISH
3