AME MM-2 Installatiehandleiding - Pagina 5

Blader online of download pdf Installatiehandleiding voor {categorie_naam} AME MM-2. AME MM-2 18 pagina's.
Ook voor AME MM-2: Gebruikershandleiding (20 pagina's)

AME MM-2 Installatiehandleiding

Wiring Description

N
Wire Destination
1
Lock Normally Closed Contact
2
Lock Common Contact
3
Lock Normally Opened Contact
4
Unlock Normally Closed Contact
5
Unlock Common Contact
6
Unlock Normally Opened Contact
7
Indicators Output
8
Power Supply
9
Siren Output
10
Trunk Release Output " " 300 mA
11
Arm Output
12
13
Door Trigger Input with selectable
polarity
14
Negative Programmable Input with
two options:
1. Trunk Trigger Input
2. Optional Sensor Pre Warn Input
15
Ignition Input
16
Ground " "
Power Immobiliser Relay
LED Output
RF Base Station Socket

System Verification

1. Connect the Car Battery
2. Check the following functions and features:
Arm/Disarm
Silent Arm/Silent Disarm
Panic
Shock Sensor and Optional Sensor Sensitivity
Triggering the alarm by door, hood, and trunk open
Non Triggering due to shaking hood and trunk coils.
Override Switch operation
Central Door Lock operation
Auxiliary Outputs and Inputs performance
Wire Color
Note
Grey/Yellow
Grey/Red
Built in Relay
Red/Yellow
Blue/Yellow
Blue/Red
Built in Relay
Red/Black
Black/White
Built in Relay Contact. Connect to the indicators feed wire via Fuse 15A.
Use diodes to separate indicator wires if necessary.
Connect to +12V contact of the car battery via 20A fuse.
Red
Brown
+ 2 A
Blue/Black
Connect to the coil of the trunk release relay.
" "300 mA when Armed. To control an extra normally closed blocking
Brown/White
relay.
The input has the "Dome Light Cars" selectable option. (Installer
Green
function 1).
The installer function 2 set the input polarity.
Grey
1. If the Trunk Trigger Input is selected the alarm will be triggered as soon
as the input is grounded in the armed stage.
While remote trunk opening in armed stage the input will be overridden
until 10 seconds of trunk is closed.
The trunk pin switch should be mounted onto the car body metal. Make
sure the switch is reliable disconnected when the trunk cowl is closed,
and will be grounded as soon as the trunk is opened.
2. If the Pre Warn Input is selected and the input is grounded when armed,
the siren will emit a few short beeps.
While remote trunk opening in armed stage both the pre warn and door
trigger input will be overridden until 10 seconds of trunk is closed. This
allows using the door input as the door and trunk trigger input at the same
time.
Orange
Connect the Ignition line, where +12V appears at switching the
ignition on and stays while cranking.
Black
Connect to the car body.
Other Connections
Two Side Exited
Built in normally closed relay.
Black Wires
2 pin White Connector
4 pin Black Connector
See Central Door Lock Connection Diagrams
Installation manual
AME MM 2 Car Alarm System
4