Switch Specification:
Initilisation Procedure:
This initialisation procedure is only necessary at the very first operation of your workstation. The only time this procedure
will need to be redone is if the control boxes are changed, the desk has been powered off for any long period of time or
the workstation has been moved or shifted around. Before performing this procedure, please ensure that all equipment
and obstacles that will impede the legs reaching their lowest point have been removed.
To perform the initialisation procedure:
1.
Presss and hold the down arrow ("Parallel Down") button until the workstation has reached its lowest position
2.
Release the down arrow ("Parallel Down")
3.
Press and hold the down arrow ("Parallel Down") again for 6 seconds, the workstation should lower and rise a
few mm during these 6 seconds
4.
The workstation has now been initialised and is ready for normal operation
Normal Operation:
To run the workstation up and down, press the "Parallel Up" and "Parallel Down" button, keeping it down pressed until the
workstation reaches your desired height. Whilst in operation the LED switch will count up or down, depending on the
movement of your workstation. Once stopped, the LED display should continuously show the height of the workstation.
Store a memory position:
1.
Run the workstation to your desired height
2.
Press the "Store" button and the display will flash "S" for two seconds
3.
Within two seconds, press Memory 1, 2 or 3. The position has now been stored
4.
To abort the sequence, press the "up" or "down" button whilst the "S" is flashing. Alternatively you can wait until
the display has stopped flashing and the height of the table is once again shown
Recalling a memory position:
1.
Press and hold the "Memory 1" button until the desk reaches its stored position and stops
2.
For other memory recalls, repeat this procedure for "Memory 2" and "Memory 3" positions