= Suggested spare part.
D E S C R I P T I O N
Refrigeration compressor
Refrigeration compressor
Refrigeration compressor
Refrigeration compressor
Fan motor
Fan motor
Fan motor
Fan blade
Fan blade
Fan grid
DMC5 Air Dryer Controller 115V
DMC5 Air Dryer Controller 230V
DMC5 Probe
Lighted main switch
Condensate drain valve/strainer
Condensate drain solenoid valve – body
Condensate drain solenoid valve – coil 115V
Condensate drain solenoid valve – coil 230V
By-pass solenoid valve - body
By-pass solenoid valve – coil 115V
By-pass solenoid valve – coil 230V
NOTE:
When ordering a replacement part, have information from data nameplate available.
Only qualified personnel should perform maintenance operations.
Prior to performing any maintenance or service, be sure that:
• Ensure that the power is off and the unit is at atmospheric pressure.
• Main power circuit breaker is in the off position per lock out/tag out procedures.
• Ensure that maintenance personnel have read and understand the safety and operations instructions in
this manual.
• High temperature conditions exist during operation of system. Avoid contact until system or component
has dissipated heat.
SYMPTOM
The machine doesn't start.
The compressor doesn't work.
The condenser fan doesn't work.
DewPoint too high.

6.2 REPLACEMENT PARTS

P a r t N u m b e r
5015135001
5015135005
5015110001
5015110004
5210135005
5210135010
5215000010
5215000005
5215000019
5225000010
5620130105
?
5625NNN005
5450SZN010
64355MN012
64320FF005
64N22MM035
64N22MM005
64120SS005
64N22MM055
64N22MM060
7.1 TROUBLESHOOTING
POSSIBLE CAUSE - SUGGESTED ACTION
Check inlet power.
Verify electric wiring connections.
Check continuity of On/Off switch
Activation of the internal thermal protection - wait for 30 minutes, then retry.
Verify the electric wiring.
Replace the internal thermal protection.
If present, replace the start-up relay.
If present, replace the start-up capacitor.
If present, replace the run capacitor.
If the compressor doesn't work yet, replace it.
Verify the electric wiring.
If the fan still doesn't work, replace it.
The dryer is off - switch it on.
The compressor doesn't work - see specific point.
The condenser fan doesn't work - see specific point.
The inlet air is too hot - restore the nominal conditions.
The inlet air flow rate is higher than the rate of the dryer - reduce the flow rate -