Coastal WEATHERPAK MTR Gebruikershandleiding - Pagina 19
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Coastal WEATHERPAK MTR. Coastal WEATHERPAK MTR 20 pagina's.
•
Be sure the Receiver/Display unit is plugged in and turned on. Double check the power cord connections at
the wall, power supply and back of the Receiver/Display box. If this does not correct the problem, contact
Coastal Environmental Systems' Service Department.
5-2.3
Data Transmission Indicator Light
Every time a WEATHERPAK
30 seconds); the amber colored data light will flash, signifying the WEATHERPAK
being received. If the light does not flash, check the following:
•
Double check the power cord. Be certain the Receiver/Display unit is plugged in and turned on. Check the
power indicator light on the "On/Off" button on the front panel.
•
Make certain you have direct line-of-sight to the WEATHERPAK
blocked by an obstruction (hills, vehicles, steel buildings, etc.).
•
Check to see that both the WEATHERPAK
•
Reset the system by removing the WEATHERPAK
10 seconds, and then replace the WEATHERPAK
•
Check the tripod battery voltage and be certain the batteries are properly aligned (positive towards the top of
).
the tower
Replace batteries if necessary. (See Section 5-3.)
5-2.4
The Computer
There is data on the display, but no data reaches the computer.
The WEATHERPAK
data collection software such as INTERCEPT™). If your computer is not receiving the data it is probably
caused by one of the following:
•
Check all the connections from the Receiver/Display to the computer. If the connections appear to be
sound, this indicates the weather station and Receiver/Display box are both working properly and the
fault is probably with the computer.
•
If the issue is with ALOHA
computer. Some earlier versions of ALOHA
an automatic weather station like the WEATHERPAK
software downloads, support, and information at its web site:
http://www.epa.gov/OEM/content/cameo/index.htm
If indications are that data is not being received by the computer, whether you are running ALOHA
•
another software program, there is a probable virtual COM port configuration problem. ALOHA
receive data on COM 1, 2, 3 or 4. If these ports are in use by other devices or if Windows
arbitrarily assigned another virtual COM port for use with ALOHA
received by the software. A discussion and remedy can be found in Appendix B, located in the back of
this manual.
Error messages while running plume model.
These are not related to the use of the WEATHERPAK
•
Consult the CAMEO
•
Contact Coastal Environmental Systems' Service Department. We are not certified CAMEO
trainers or representatives, but we may be able to help.
5-3
REPLACING TOWER BATTERIES AND FUSE
WARNING: DO NOT LEAVE BATTERIES IN TOWER WHEN STORING OR SHIPPING TOWER ASSEMBLY.
BATTERIES MAY LEAK CAUSING DAMAGE TO UPPER TOWER SECTION.
Tower Batteries
5-3.1
The WEATHERPAK
Rechargeable and bargain batteries do not perform well in the WEATHERPAK
P/N: 0302-140-001 Rev. D
®
that is within range of the Receiver/Display transmits data (typically every
®
is designed to deliver weather data to a computer and plume modeling software (or other
®
, be certain the most recent version of the software is installed on the
®
®
/ALOHA
web site: http://www.epa.gov/OEM/content/cameo/index.htm.
MTR uses ten alkaline D-cell batteries, located in the upper vertical section of the tower.
®
, that it is within 5 to 7 miles, and not
antenna and the receiving antenna are securely connected.
®
from the KamLock connector on the tripod tower. Wait
on the tower.
®
(e.g. ver. 5.2.1) need to be upgraded in order to work with
®
. The U.S. EPA provides CAMEO
.
®
and are coming from the plume modeling software
WEATHERPAK
User's Manual
data carrier signal is
®
/ALOHA
®
has
, the weather station data will not be
®
/ALOHA
®
. Always use high quality
®
MTR
®
®
or
®
must
.
®
19