aero-stream 100343 Beknopte handleiding - Pagina 2
Blader online of download pdf Beknopte handleiding voor {categorie_naam} aero-stream 100343. aero-stream 100343 3 pagina's.
connections are tight, pinch the large air line after the black "tee"
(on the tank side of the tee) to deadhead the pump. The sound
output of the pump will change. If the light goes out the air switch
is o.k. and go to step 4. If the light does not go out call Aero-
Stream®.
4. Plug the float into the alarm box. Open the septic tank cover.
Make sure the float switch is hanging completely vertically in the
tank. If not, using a stick, push the float downward until the cord
and float are vertical. If the light goes out go to step 5.
5. Allowing the float to hang from its' bracket, adjust the float
switch clamp on the mast upward until the light goes out.
6. If the light does not go out call Aero-Stream®.
Function Configuration
The Aero-ALERT™ can be configured to defeat the audible signal
or defeat the air switch to make the unit function as a high water
alarm only.
1. To defeat the audible signal gently slide the green connector
from the terminal and leave loose inside enclosure (figure 6).
2. To defeat the air switch gently slide the yellow connector from
the terminal and leave loose inside enclosure (figure 6).
Options:
P/N: 101859 - DC Power supply to operate the Aero-ALERT™ on
120 VAC.
Figure 7
PN 101953
To Float
Switch
Figure 4
Figure 5
Figure 6