Aktobis WDH-BGP10S Snelstarthandleiding - Pagina 5
Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Aktobis WDH-BGP10S. Aktobis WDH-BGP10S 8 pagina's. Power heater with hose connection
Instructions for use:
1. Commissioning
1.1 Insert the mains plug properly into the socket.
1.2. Select the desired unit power with the operating power adjustment knob (left-hand knob).
0
= Off
= Fan operation (cold blower)
= Heating mode (operating strength with 5,000 W heating power)
= Heating mode (operating strength with 10,000 W heating power)
1.3 Now set the desired temperature switch-off point (0 ~ 40°C) with the thermostat control dial (right-hand knob).
This is best done as follows: Turn the thermostat knob to the highest temperature (Max.) and let the heater run
until your desired temperature value is reached. Now turn (adjust) the control downwards towards the minimum
until the heating function switches off automatically. Now leave the control dial (thermostat) in this position and
whenever it gets colder in the room, the appliance automatically starts heating and when the adjusted
temperature is reached again, the heating element of the appliance automatically switches off again!
1.4 The fan heater is equipped with a cool-down overrun, i.e. if the internal thermostat detects that the temperature
inside is too high or even rises again after the unit has been switched off, the unit automatically switches on the
fan to cool down (cool-down overrun). This process also occurs when the operating strength adjustment knob
is in the "Off" (0) position ! For these reasons, it is important that you do not unplug the unit from the mains for
approx. 3-4 minutes after the end of operation !
Note: The fan of the heater is not controlled by the thermostat. If the selected target temperature is reached,
the heating element switches off automatically, but the fan continues to run !
2. Hose connection / hose discharge
2.1. If you want to operate the fan heater with a hose, make sure that it is heat-resistant and has a diameter of at
least 305 mm. In addition, we recommend a maximum hose length of 7 metres.
2.2. When routing the hose, make sure that the hose is not bent/angled too much so that no air/heat build-up can
occur. See the following diagram !
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: [email protected]