Air & Allied Sales UGC2005M Gebruiksaanwijzing - Pagina 3

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Air & Allied Sales UGC2005M. Air & Allied Sales UGC2005M 10 pagina's. Solvent based spray gun cleaner

Installation of containers
WARNING: DO NOT SMOKE OR USE OPEN FLAME NEAR CABINET.
UGC4005 ONLY Take 1 x 25litre drum of clean solvent, remove 5 litres and fill an empty 5 litre
container.
UGC5005 ONLY Take 2 x 25litre drum of clean solvent, remove 5 Litres from each drum and fill
2 x empty 5 litre container.
1
Disconnect quick release coupling by lifting the locking ring and bring outside of machine (See
Diagram 1).
2
Insert hose with suction filter into drum of solvent and enter drain tube.
Push solvent container/s under machine aligning filler neck with male part of quick release coupling.
3
4
Reconnect quick release coupling.
UGC4005/UGC5005 ONLY Place the full 5 litre container under the centre of the machine next to
5
the 25 litre drum of solvent and insert black 6mm nylon tube with wire clip in to the full 5 litre
container (Repeat this step for UGC5005).
6
Turn drain valve lever to vertical position (see diagram 2).
7
Underneath the machine at the rear are the earthing wire(s), the crocodile clip(s) must be attached to
any metal solvent container(s) if used (these are not supplied by Unic international).
MAINTENANCE CHECK:
Grid Filter:
It is recommended that the Green Grid Filter inside the tank under the Work Screen is
changed once a month.
Suction Filter:
It is recommended that the Suction Filter be cleared thoroughly every time the cleaning
fluid is replaced.
Please note:
If the Suction Filter is damaged or removed, the Pump Warranty is void.
Lubrication:
The air valve is lubricated at the factory and designed to operate without additional
lubrication. If added lubrication is desired, every 500 hours of operation (or monthly)
Remove the hose from the pump air inlet and add two drops of machine oil to the air
inlet.
Air & Allied Sales (Pacific) Pty Ltd