Bobrick MetroSeries 1550 Handleiding voor installatie-instructies - Pagina 6

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Bobrick MetroSeries 1550. Bobrick MetroSeries 1550 14 pagina's. High pressure laminate (hpl) toilet partitions

STEP 3
INSTALL WALL BRACKETS AND WALL POSTS
A. Measure and mark the locations of centerlines for all
the stiles and panels on walls.
B. Using the wall brackets as templates, measure
and mark the location of all mounting holes, plumb
according to dimensions shown in illustrations (Fig.
3a, 3b, 3c).
C. Use #19 (.166) drill bit (4.2mm) for 2" (50mm) deep
pilot holes into adequate wall backing.
D. Secure wall brackets with 1002495 screws.
These mounting points require wall backing.
Obtain Dimension from Bobrick Layout Sheet.
Fig. 3b: Overhead-Braced Alcove Closed
Layout.
Panel
Centerline
64''
(163cm)
18''
64''
(46cm)
(163cm)
Floor Anchors
Page 6
Form No. 1550-69 r4/20/18
Stile
Centerline
43''
(109cm)
18''
(46cm)
© 2018 Bobrick Washroom Equipment, Inc.
Fig. 3a: Front-Entry Corner Layout with
Wall Post.
Wall Post
54-1/2''
(138cm)
67-1/2''
27-1/2''
(171cm)
(69cm)
41''
(104cm)
14-3/4''
(37cm)
WALL POST #1002250
A. Determine the location and hole of the 1" x 1-1/2"
(25 x 40mm) stainless steel wall post being installed.
Outside edge of wall post to be in-line with outside
edge of keeping stile. The wall must have adequate
backing at mounting location to support door hung in
place.
B. Install wall post at given height and fasten, plumb in
both directions to wall with (5) wall screws provided.
Install (2) post end caps and (5) mounting hole plugs.
C. Attach door with through bolts provided as you install
door(s) on pages 13.
Fig. 3c: Floor-Anchored or Ceiling-Hung
Alcove Open Layout.
Panel Centerline
64''
(163cm)
18''
(46cm)
Floor Anchors
Panel
Centerlines
(163cm)
18''
(46cm)
Floor Anchors
Panel Centerline
64''
(163cm)
18''
(46cm)
Printed in U.S.A.
64''