American Standard Claridge Centerset Lavatory Faucet 6054.XXX Handleiding voor installatie-instructies - Pagina 3

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} American Standard Claridge Centerset Lavatory Faucet 6054.XXX. American Standard Claridge Centerset Lavatory Faucet 6054.XXX 7 pagina's. Centerset lavatory faucet with the speed connect drain

American Standard Claridge Centerset Lavatory Faucet 6054.XXX Handleiding voor installatie-instructies
6
ATTACH CABLE CONNECTOR
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4" O.D.
Fig. B.
7
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes. Fig. B.
Note: If STOPPER (2) does not open and close properly then refer
to the "troubleshooting section" of these instructions.
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
Fig. A.
1
2
1/2" PIPE
THREAD
2
FLEXIBLE
SUPPLIES
HOT
3
Fig. B.
1
2
COUPLING
NUT
3/8 O.D.
BULL-NOSE
RISERS
3/8" COMPRESSION
CONNECTION
COLD
1-1/4" O.D.
1
3
COMPRESSION
NUT
FERRULE
M 9 6 8 6 3 2