American Standard COLONY 2359 Installatie-instructies - Pagina 3
Blader online of download pdf Installatie-instructies voor {categorie_naam} American Standard COLONY 2359. American Standard COLONY 2359 5 pagina's. American standard renaissance el total toilet installation instructions
10
FILL
VALVE
FLAPPER
THREADED
SHANK
LOCK NUT
COUPLING NUT
(HAND TIGHT ONLY)
12
CARE AND CLEANING
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth.
Avoid detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or
abrasive pads on your toilet seat. Some bathroom chemicals and cosmetics may damage the seat's finish.
WARNING:
Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage
!
fittings in the tank. This damage can cause leakage and property damage.
American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners
containing chlorine (calcium hypochlorite).
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO.
735076-400-XXX
735098-400-XXX
7381006.402.0070A
738570-1030A
7381009-0070A
7381007-402-0070A
7381007-404-0070A
730512-0070A
7381024-400-0070A
7381024-402-0070A
047192-XXX0A
034783-XXX0A
5329.XXX
REFILL
TUBE
TANK
LEVER
HOOK
FLOAT
CUP
FLUSH
VALVE
Diagram 1
REPAIR PARTS LIST
DESCRIPTION
4037 TANK COVER
4392 TANK COVER
FLUIDMASTER 300A VALVE
FLUIDMASTER REFILL TUBE
FLUIDMASTER REFILL CLIP
FLUIDMASTER FLUSHVALVE
FLUIDMASTER FLUSHVALVE
TANK COUPLING KIT #232
FLUIDMASTER FLAPPER ASSEMBLY
FLUIDMASTER FLAPPER ASSEMBLY
TRIP LEVER ASSEMBLY LH
BOLT CAP KIT #128
SEAT
ADJUSTMENTS
a. Adjust water level. Water level
should be adjusted to level indicated
on tank by adjusting float cup.
See Step 11 for water level adjustment
method.
b. If bowl fails to siphon, an adjustment
may be required with the lift chain.
Simply remove the chain from
the retainment clip and take up slack
on the chain, and reinsert on lift rod.
Make sure the chain is not too taught.
- 3 -
11
TAB
FLOAT
CUP
Turn on water supply. Let the
toilet cycle once. Adjust the
water to desired level by
depressing TAB on FLOAT
CUP and moving FLOAT CUP
up or down.
TANK NUMBER
7301186- 10 0 R ev. B