American Standard 2805L Installatiehandleiding - Pagina 11
Blader online of download pdf Installatiehandleiding voor {categorie_naam} American Standard 2805L. American Standard 2805L 15 pagina's. Lifetime / evolution and renaissance whirlpools and bathtubs
WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
!
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
. All building materials and wiring should be routed away from the pump body and heater (if equipped).
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
GFCI CIRCUIT REQUIREMENTS:
The whirlpool should be installed on a 120 vac,
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
The whirlpool should be installed on a 120 vac,
GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
Optional heater requires a separate 15 amp maximum GFCI circuit.
WIRE SELE C T I O N G U I D E
M ot or
Hi Per f orma n ce
Rat ing
2.1 H.P.,
1.4 H.P.,
and 1.25 H. P .
15
20
1 20 VA C
G N D .
READ AND FOLLOW ALL INSTRUCTIONS
Ma xi m u m d is ta nce from
f u se bo x to mo tor
5 0 '
10 0 '
15 0'
1 1 5 V Po we r Line
12
1 0
11
FOR MODEL NUMBERS:
amp dedicated
amp dedicated
PUMP/MOTOR
ELECTRICAL DIAGRAM
c hart a re rec omme ndat i ons
2 00'
8
8
2732, 2422, 2425, 2645,
2771, 2805, 2908
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
LA, LAC, VA, VAC
6060, 2775, 2773, 2711, 2901
ALL MODELS
7236, 2774
MODELS ENDING IN SUFFIX
L, LC, V, VC
The siz es shown on t his
for c opper c onduct or s
onl y. Always foll ow
l ocal and natio nal
ele ctric al code s
753737-100 Rev. B